MedElevator Войти в исследования
← Поиск публикаций

DOI 10.13107/jocr.2026.v16.i05.7298

Медицинская библиотека · Journal of orthopaedic case reports · 2026

The Computed Tomography-based Morphometry of Thoracolumbar Junction (T11-L2) in Western Indian Population: Implications for Transpedicular Screw Fixation.

Yadav Sandeep Kumar, Kishan Rama, Parihar Kishore, Rajnish Rajesh Kumar, Meena Anil, Meena Rahul

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Morphometric data for safe transpedicular screw placement at the thoracolumbar junction (T11-L2) remain limited for Indian populations, despite ethnic variations affecting screw sizing and complications. This study provides prospective computed tomography-based reference values for Western India.

MATERIALS AND

METHODS

Prospective analysis of 200 consecutive adults (≥20 years; 110 males, 90 females) with back pain but normal thoracolumbar imaging (June 2021-August 2023) at a Western Indian tertiary center was conducted. Ethical approval taken from Institutional Ethics Committee, AIIMS Jodhpur (IEC No.- AIIMS/IEC/2022/4070). The bilateral pedicle width, interpedicular distance (IPD), anterior cortex depth, and transpedicular angle measured at T11-L2 using digital imaging and communications in medicine viewer (1-2 mm slices). Means ± standard deviation were compared by sex using unpaired t-tests (P < 0.05 significant; Excel).

RESULTS

Pedicle width increased caudally (T11: 5.14 ± 0.87 mm; L2: 6.39 ± 0.89 mm), with male > female at T12/L1 (P < 0.01). IPD rose from T11 (1.74 ± 0.20 cm) to L2 (2.15 ± 0.20 cm; L1 P = 0.039 by sex). Transpedicular angle: T11 (19.96 ± 2.20°) to L2 (23.06 ± 1.42°; all P < 0.05 by sex). Anterior cortex depth peaked at L1 (5.05 ± 0.86 cm). Safe screws: Thoracic 4.5-5.5 mm, lumbar 5.5-6.5 mm.

CONCLUSION

Western Indian norms show narrower pedicles than Western data, aligning with other Indian series but adding a T11-L2 focus. This aids in ethnicity-specific screw selection to reduce misplacement in thoracolumbar fixation.

Для цитирования: Yadav Sandeep Kumar, Kishan Rama, Parihar Kishore, Rajnish Rajesh Kumar, Meena Anil, Meena Rahul. The Computed Tomography-based Morphometry of Thoracolumbar Junction (T11-L2) in Western Indian Population: Implications for Transpedicular Screw Fixation.. Journal of orthopaedic case reports. 2026. DOI: 10.13107/jocr.2026.v16.i05.7298.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.