MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/diagnostics13203179

Медицинская библиотека · Diagnostics (Basel, Switzerland) · 2023

Laser Flare Photometry to Monitor Childhood Chronic Uveitis: A Preliminary Report of a Monocentric Italian Experience.

Maccora Ilaria, De Libero Cinzia, Peri Matilde, Danti Gioia, Rossi Alessio, Marrani Edoardo, Pasqualetti Roberta, Pagnini Ilaria, Mastrolia Maria Vincenza, Simonini Gabriele

СтатьяПеревод в очереди

Аннотация

Background

Childhood chronic non-infectious uveitis (cNIU) is a challenging disease that needs close monitoring. Slit lamp evaluation (SLE) is the cornerstone of ophthalmological evaluation for uveitis, but it is affected by interobserver variability and may be problematic in children. Laser flare photometry (LFP), a novel and objective technique, might be used in children with uveitis. Aim: The aim of this study was to attempt the use of LFP in cNIU clinical practice.

Methods

Children, attending the Rheumatology Unit and who were scheduled to receive ophthalmological evaluation, were prospectively enrolled to concomitantly receive SLE and LFP. SLE was performed blind to LFP measure. Demographic, laboratory, clinical, and ophthalmology data were collected.

Results

A total of 29 children (58 eyes) were enrolled, including 3 with juvenile idiopathic arthritis without uveitis (JIA-no-U), 15 with JIA-associated uveitis (JIA-U), and 11 with idiopathic chronic uveitis (ICU). We observed significantly higher LFP values in the eyes of children with uveitis compared to the others (10.1 IQR 7.1-13.6 versus 6.2 IQR 5.8-6.9, p = 0.007). Accordance between the SLE and LFP measures, at baseline (ρ.498, p < 0.001) and during the follow-up (LFP II ρ 0.460, p < 0.001, LFP III ρ 0.631, p < 0.001, LFP IV ρ 0.547, p = 0.006, LFP V ρ 0.767, p = 0.001), was detected. We evaluated significant correlation between LFP values and the presence of complications (ρ 0.538, p < 0.001), especially with cataract formation (ρ 0.542, p < 0.001).

Conclusions

In this cohort, LFP measurements showed a good correlation with SLE. LFP values showed a positive correlation with the presence of complications. LFP might be considered as a reliable objective modality to monitor intraocular inflammation in cNIU.

Для цитирования: Maccora Ilaria, De Libero Cinzia, Peri Matilde, Danti Gioia, Rossi Alessio, Marrani Edoardo, Pasqualetti Roberta, Pagnini Ilaria, Mastrolia Maria Vincenza, Simonini Gabriele. Laser Flare Photometry to Monitor Childhood Chronic Uveitis: A Preliminary Report of a Monocentric Italian Experience.. Diagnostics (Basel, Switzerland). 2023. DOI: 10.3390/diagnostics13203179.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.