MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jim.2016.02.017

Медицинская библиотека · Journal of immunological methods · 2016

Testing for myositis specific autoantibodies: Comparison between line blot and immunoprecipitation assays in 57 myositis sera.

Cavazzana Ilaria, Fredi Micaela, Ceribelli Angela, Mordenti Cristina, Ferrari Fabio, Carabellese Nice, Tincani Angela, Satoh Minoru, Franceschini Franco

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

OBJECTIVE

To analyze the performance of a line blot assay for the identification of autoantibodies in sera of patients affected by myositis, compared with immunoprecipitation (IP) as gold standard.

METHODS

66 sera of patients with myositis (23 polymyositis, 8 anti-synthetase syndromes, 29 dermatomyositis and 6 overlap syndromes) were tested by commercial LB (Euroimmun, Lubeck, Germany); 57 sera were analyzed also by IP of K562 cell extract radiolabeled with (35)S-methionine. Inter-rater agreement was calculated with Cohen's k coefficient.

RESULTS

Myositis-specific antibodies (MSA) were detected in 36/57 sera (63%) by IP and in 39/66 sera (59%) by LB. The most frequent MSA found by LB were anti-Jo1 and anti-Mi2 found in 15% (10/66) of sera, followed by anti-NXP2 and anti-SRP detected in 106% (7/66) of sera. Anti-TIF1gamma and anti-MDA5 were found in 6 (9%) and 5 sera (7.6%), respectively. A good agreement between methods was found only for anti-TIF1γ, anti-MDA5 and anti-NXP-2 antibodies, while a moderate agreement was estimated for anti-Mi2 and anti-EJ. By contrast, a high discordance rate for the detection of anti-Jo1 antibodies was evident (k: 0.3). Multiple positivity for MSA were found in 11/66 (17%) by LB and 0/57 by IP (p: 0001). Comparing the clinical features of these 11 sera, we found total discrepancies between assays in 3 sera (27.3%), a relative discrepancy due to the occurrence of one discordant autoantibody (not confirmed by IP) in 5 cases (45.5%) and a total discrepancy between LB and IP results, but with a relative concordance with clinical features were found in other 3 sera (27.3%). The semiquantitative results do not support the interpretation of the data.

CONCLUSIONS

The use of LB assay allowed the detection of new MSA, such as anti-MDA5, anti-MJ and anti-TIF1gamma antibodies, previously not found with routine methods. However, the high prevalence of multiple positivities and the high discondant rate of anti-Jo1 antibodies could create some misinterpretation of the results from the clinical point of view. These data should be confirmed by enlarging the number of myositis cases.

Для цитирования: Cavazzana Ilaria, Fredi Micaela, Ceribelli Angela, Mordenti Cristina, Ferrari Fabio, Carabellese Nice, Tincani Angela, Satoh Minoru, Franceschini Franco. Testing for myositis specific autoantibodies: Comparison between line blot and immunoprecipitation assays in 57 myositis sera.. Journal of immunological methods. 2016. DOI: 10.1016/j.jim.2016.02.017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.