MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jhsa.2007.07.018

Медицинская библиотека · The Journal of hand surgery · 2008

Use of dynamic distraction external fixation for unstable fracture-dislocations of the proximal interphalangeal joint.

Ruland Robert T, Hogan Christopher J, Cannon David L, Slade Joseph F

СтатьяПоддержка правительства СШАПеревод в очереди

Аннотация

PURPOSE: Unstable fracture-dislocations of the proximal interphalangeal (PIP) joint remain a difficult management problem, often leading to residual pain, stiffness, and recurrent instability. In a military setting, an easily applied, simple to operate, and inexpensive device becomes an attractive option. The purpose of this clinical investigation was to retrospectively review use of dynamic distraction external fixation (DDEF) for unstable fracture-dislocations and pilon injuries of the PIP joint in an active-duty population.

METHODS

The fixator is assembled under a local anesthetic from three 1.4-mm (0.045-inch) K-wires and rubber bands. It uses the principles of a lever and ligamentotaxis to assist and maintain reduction. Thirty-four members of the Armed Services, 27 men and 7 women (average age, 30 y), had DDEF for pilon fractures and unstable fracture-dislocations of the PIP joint. A retrospective review of these individuals was conducted. Final range of motion was determined from the clinical records at the final visit.

RESULTS

There were 26 PIP fracture-dislocations (3 chronic, average 6 weeks) and 8 PIP pilon injuries. The average follow-up period was 16 months (range, 6-84 months). The final arc of motion at the PIP joint averaged 88 degrees , and the average distal interphalangeal joint arc of motion was 60 degrees . Eight patients experienced superficial pin-track infections that were easily controlled with oral antibiotics. There were no cases of septic arthritis or osteomyelitis requiring intravenous antibiotics or premature fixator removal. Loss of reduction did not occur. All patients returned to their prior level of activity and duties.

CONCLUSIONS

Our results are comparable with other techniques used in the management of unstable PIP joint fracture-dislocations. Easily applied and simple to operate, DDEF is a valuable addition to the hand surgeon's armamentarium. We recommend its use for both primary and adjunctive treatment of acute and chronic unstable PIP joint fracture-dislocations and for primary treatment of PIP pilon injuries.

TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic IV.

Для цитирования: Ruland Robert T, Hogan Christopher J, Cannon David L, Slade Joseph F. Use of dynamic distraction external fixation for unstable fracture-dislocations of the proximal interphalangeal joint.. The Journal of hand surgery. 2008. DOI: 10.1016/j.jhsa.2007.07.018.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.