MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jocmr.2026.102727

Медицинская библиотека · Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2026

Impact of reconstruction type on late gadolinium enhancement scar quantification at 3-Tesla: Magnitude vs. phase-sensitive inversion recovery.

Moafi Aida, Shergill Simran, Adlam David, Samani Nilesh J, McCann Gerry P, Arnold J Ranjit

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

BACKGROUND

The identification of myocardial scar using late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) is well established, providing diagnostic and prognostic value in both ischemic and non-ischemic cardiomyopathies. Phase-sensitive inversion recovery (PSIR) provides more consistent image contrast compared with magnitude (MAG) reconstructions. However, the impact of reconstruction method on scar quantification remains uncertain.

METHODS

One-hundred and thirty-six patients from three prospectively enrolled cohorts with chronic myocardial infarction (>3 months post-infarction), representing distinct infarct phenotypes, underwent contrast-enhanced research CMR. LGE images were acquired using either a breath-hold, segmented spoiled gradient-echo or free-breathing, motion-corrected, balanced steady-state free precession sequence. Infarction was quantified on matched, short-axis MAG and PSIR reconstructions using the full-width at half-maximum method, with total infarct size expressed in grams (g) and as percentage of left ventricular mass. The primary analysis compared scar quantification between the two reconstruction methods.

RESULTS

Compared with MAG, PSIR demonstrated significantly higher median scar mass (13.7 g [6.0-25.7] vs. 8.9 g [4.4-16.6], p<0.001) and percentage of left ventricular mass (14.2% [7.5-21.9] vs. 10.6% [5.4-14.2], p<0.001). Inter-method agreement was moderate for both absolute and relative scar mass (intraclass correlation coefficients: 0.76 [95% CI: 0.33, 0.89] and 0.74 [95% CI: 0.20, 0.89], respectively), with a systematic, proportional difference on Bland-Altman analysis, with consistently higher scar mass by PSIR (mean bias: +5.01 ± 5.87 g; limits of agreement: -6.50 to +16.51 g and +4.54 ± 4.62%; limits of agreement: -4.51 to +13.60%).

CONCLUSION

Quantification using PSIR yields higher infarct sizes compared with MAG LGE reconstructions. This emphasizes the importance of using a consistent reconstruction method when quantifying scar burden.

Для цитирования: Moafi Aida, Shergill Simran, Adlam David, Samani Nilesh J, McCann Gerry P, Arnold J Ranjit. Impact of reconstruction type on late gadolinium enhancement scar quantification at 3-Tesla: Magnitude vs. phase-sensitive inversion recovery.. Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance. 2026. DOI: 10.1016/j.jocmr.2026.102727.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.