Biomechanical Cadaveric Study of a Method for Foveal Reinsertion of the Triangular Fibrocartilage Complex Without Foveal Perforation.

Tibau-Alberdi Maria, Ferreres-Claramunt Àngel, Del Valle-Jou Montserrat, Pérez-Abad Miguel, Noriego-Muñoz Diana, Berlanga-De Mingo Daniel, Rodríguez-Baeza Alfonso

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Triangular fibrocartilage complex (TFCC) injuries can compromise distal radioulnar joint (DRUJ) stability, especially when the foveal insertion is affected. Various arthroscopic and open repair techniques have been described, including bone tunnels and anchors, but no consensus exists on the optimal approach. This biomechanical study evaluates a modified foveal reinsertion technique based on Mantovani's method for Atzei class 2 lesions, which avoids foveal perforation.

METHODS

Twenty cryopreserved upper extremities (13 female, 7 male specimens; mean age 83 years) were tested. Radius displacement relative to the ulna was measured in 3 conditions: intact TFCC, sectioned TFCC (simulating a foveal lesion), and repaired TFCC. Tests were performed in neutral rotation, 60° pronation, and 60° supination, applying a 3 kg dorsal and volar load to simulate functional stress. Displacement was recorded using the FASTRAK 3D electromagnetic system.

RESULTS

Results showed a significant increase in displacement after TFCC sectioning in all positions, confirming the fovea's role in stability. After repair, displacement values returned to levels comparable with the intact TFCC, with no statistically significant differences.

CONCLUSIONS

This technique preserves the TFCC's anatomical footprint, avoids bone tunnels (reducing fracture risk and radiation exposure), and distributes forces more evenly across the insertion. It also requires no special devices, making it a cost-effective and reproducible option. This study demonstrates that the proposed technique restores DRUJ stability.

Для цитирования: Tibau-Alberdi Maria, Ferreres-Claramunt Àngel, Del Valle-Jou Montserrat, Pérez-Abad Miguel, Noriego-Muñoz Diana, Berlanga-De Mingo Daniel, Rodríguez-Baeza Alfonso. Biomechanical Cadaveric Study of a Method for Foveal Reinsertion of the Triangular Fibrocartilage Complex Without Foveal Perforation.. Hand (New York, N.Y.). 2026. DOI: 10.1177/15589447261463807.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.