STUDY

DESIGN

Prospective, observational study.

OBJECTIVE

To evaluate biomechanical changes associated with cervical arthrodesis using a cylindrical titanium cage.

SUMMARY OF BACKGROUND DATA: Anterior cervical discectomy and fusion (ACDF) is the "gold standard" for treating cervical disc disease. In an effort to avoid the morbidity associated with autogenous bone graft harvesting, cervical cages are used to achieve fusion. The cages should allow for restoration and maintenance of natural disc height, angulations, and displacements at the operated levels.

METHODS

Fifty-four patients underwent standard ACDF using a "stand alone" cylindrical cage implant. Lateral radiographic views of the cervical spine were obtained before surgery, on the first day postoperatively, and at 12 months postoperatively. Disc height, vertebral alignment, angle of lordosis, and range of motion at operated levels were quantified prospectively by distortion compensated Roentgen analysis.

RESULTS

At 12 months postoperatively, solid fusion was achieved but the cylindrical cage failed to preserve disc height, prevent kyphosis, and preserve natural intervertebral alignment. We observed significant cage subsidence and malalignment.

CONCLUSION

We noticed several unfavorable outcomes when performing an analysis of radiographic parameters after ACDF using a cylindrical titanium cage. Thus, the use of a "stand alone" cylindrical cage in ACDF should be considered with caution.

Для цитирования: Kolstad Frode, Nygaard Øystein P, Andresen Hege, Leivseth Gunnar. Anterior cervical arthrodesis using a "stand alone" cylindrical titanium cage: prospective analysis of radiographic parameters.. Spine. 2010. DOI: 10.1097/brs.0b013e3181d259c1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.