OBJECTIVE

To analyse the clinical, radiological, and functional outcomes of robotic-arm assisted total hip arthroplasty (RA-THA) with a mean follow-up of 2 years at Hospital Clínico San Carlos, Madrid.

MATERIALS AND

METHODS

A prospective descriptive study was conducted including patients who underwent RA-THA using the Mako system (Stryker) between October 2021 and March 2024. All procedures were performed by 4 dedicated hip surgeons, excluding each surgeon's learning curve. Demographic, clinical, functional, and radiological parameters were analysed. Mean follow-up exceeded 24 months.

RESULTS

A total of 226 patients were included (52% male, 48% female), with a mean age of 64.9 ± 12.9 years. Mean follow-up was 27.1 (range 12-36) months.Preoperative diagnoses were primary hip osteoarthritis in 88.5%, developmental dysplasia in 5.8%, avascular necrosis in 3.1%, post-traumatic osteoarthritis in 1.8%, and subcapital fracture nonunion in 0.4%.Mean operative time was 87.9 ± 23.4 minutes. Intraoperative complications included 11 technical events related to marker loss (4.86%), 6 greater trochanter fractures (2.6%), and 2 calcar fractures (0.8%).Mean acetabular component positioning was 43.1 ± 3.4° of inclination and 14.2 ± 3.8° of anteversion. Native femoral offset was preserved, with a mean difference of 1.8 ± 4.5 mm. Planned limb-length discrepancy accuracy was 90% within ±5 mm. Modified Harris Hip Score (mHHS) improved from a preoperative mean of 51.7 to 87.9 at 1 year (p < 0.001).During follow-up, 5 neurological complications were recorded, 5 postoperative greater trochanter fractures, and 5 infections (2.2%), all successfully treated. 1 traumatic dislocation (0.4%) occurred without revision surgery.

CONCLUSIONS

Robotic-arm assisted THA achieves high accuracy and precision in implant positioning and limb-length restoration, with a low dislocation rate. Operative time, complication rates, and short- to mid-term functional outcomes fall within the ranges previously reported in the literature for conventional techniques. Long-term studies are required to determine the impact of robotic assistance on implant survivorship.

Для цитирования: Francés-Borrego Alberto, Valentín-Bravo Eduardo, Llanos-Sanz Sergio, Vicente-García Jesus, Bartrina-Tarrio Andres, Rodríguez-González Alberto. Analysis of clinical, radiological, and functional outcomes of robotic-arm assisted total hip arthroplasty (Mako®) at Hospital Clínico San Carlos.. Hip international : the journal of clinical and experimental research on hip pathology and therapy. 2026. DOI: 10.1177/11207000261447249.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.