MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3928/01477447-20241104-02

Медицинская библиотека · Orthopedics · 2024

An Analysis of the Complication Reports of Expandable Lumbar Interbody Cages in the Food and Drug Administration Manufacturer and User Facility Device Experience Database.

ElNemer William, Kim Andrew, Silva-Aponte Juan, Raad Micheal, Azad Tej, Durand Wesley M, Hassanzadeh Hamid, Kebaish Khaled, Jain Amit

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Expandable lumbar interbody cages (ELICs) are commonly used for interbody fusion and provide lordotic correction by lengthening the anterior column of the vertebral spine. We sought to identify unique failure mechanisms and significant differences in the types of complications associated with ELICs as reported to the Food and Drug Administration (FDA) Manufacturer and User Facility Device Experience (MAUDE) Database.

MATERIALS AND

METHODS

The MAUDE Database was analyzed for complication reports submitted for ELIC systems between January 2013 and July 2023. Reports were categorized by manufacturer, brand name, type of expandable cage, type of complication, year of complication, and reporter identity. Reports that were duplicated or had insufficient information were excluded from analysis. The top 5 manufacturers with the most implant-related complications were independently analyzed and compared.

RESULTS

A total of 821 reports were analyzed. The top 5 complications reported across all manufacturers were cage breakage during insertion (25.7%), postoperative migration without collapse (16.0%), postoperative collapse (15.6%), inserter breakage (11.1%), and tubing problems (3.0%). A significant difference was detected in complication type between manufacturers (χ2=557, P<.001). The largest number of reports (120, 14.6%) was in 2016.

CONCLUSION

With FDA approval of novel ELIC systems and the adoption of newer surgical techniques, understanding the range of potential complications is paramount in ensuring patient safety. This study of the MAUDE Database provides a comprehensive summary of adverse reported events associated with ELICs during the past decade. [Orthopedics. 2025;48(1):e7-e14.].

Для цитирования: ElNemer William, Kim Andrew, Silva-Aponte Juan, Raad Micheal, Azad Tej, Durand Wesley M, Hassanzadeh Hamid, Kebaish Khaled, Jain Amit. An Analysis of the Complication Reports of Expandable Lumbar Interbody Cages in the Food and Drug Administration Manufacturer and User Facility Device Experience Database.. Orthopedics. 2024. DOI: 10.3928/01477447-20241104-02.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.