Management of Failed Latarjet and Off-tract Hill-Sachs Lesion: Arthroscopy-assisted Remplissage and Open Eden-Hybinette Procedure.

Hsu Chen-Heng, Chuang Chieh-An, Sheu Huan, Yang Cheng-Pang, Lin Yi-Hsuan, Chiu Joe Chih-Hao

Клинический случайПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

This case report describes a 49-year-old former semi-professional judo player with recurrent right shoulder instability following his first dislocation in 2006. He underwent two unsuccessful arthroscopic Bankart repairs due to improper anchor positioning. In March 2020, an open Latarjet procedure was performed to address his ongoing instability, but he suffered another dislocation in January 2023 after a fall. Physical examination revealed a full range of motion, normal rotator cuff strength, and a positive apprehension test. X-rays showed a broken coracoid bone block, screw displacement, and a significant Hill-Sachs lesion. CT confirmed resorption of the previous coracoid graft and an off-track Hill-Sachs lesion. The patient underwent revision surgery, combining an arthroscopic-assisted Remplissage with an Eden-Hybinette procedure. One year postoperatively, the patient reported improved outcomes. Managing recurrent shoulder instability after failed surgeries is challenging. While the Latarjet procedure has a 10% recurrence rate, revision options such as distal tibial allograft and Eden-Hybinette procedures offer promising results. This case emphasizes the importance of combined surgical approaches and individualized treatment plans, particularly for patients with significant humeral bone loss, to enhance stability and reduce recurrent instability.

Для цитирования: Hsu Chen-Heng, Chuang Chieh-An, Sheu Huan, Yang Cheng-Pang, Lin Yi-Hsuan, Chiu Joe Chih-Hao. Management of Failed Latarjet and Off-tract Hill-Sachs Lesion: Arthroscopy-assisted Remplissage and Open Eden-Hybinette Procedure.. Journal of visualized experiments : JoVE. 2025. DOI: 10.3791/68382.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.