MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jsp2.1259

Медицинская библиотека · JOR spine · 2023

Three-dimensional ultrasonography could be a potential non-ionizing tool to evaluate vertebral rotation of subjects with adolescent idiopathic scoliosis.

Lee Tin Yan, Yang De, Lai Kelly Ka-Lee, Castelein Rene M, Schlosser Tom P C, Chu Winnie, Lam Tsz-Ping, Zheng Yong-Ping

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Three-dimensional (3D) ultrasonography is nonionizing and has been demonstrated to be a reliable tool for scoliosis assessment, including coronal and sagittal curvatures. It shows a great potential for axial vertebral rotation (AVR) evaluation, yet its validity and reliability need to be further demonstrated.

MATERIALS AND

METHODS

Twenty patients with adolescent idiopathic scoliosis (AIS) (coronal Cobb: 26.6 ± 9.1°) received 3D ultrasound scan for twice, 10 were scanned by the same operator, and the other 10 by different operators. EOS Bi-planar x-rays and 3D scan were conducted on another 29 patients on the same day. Two experienced 3D ultrasonographic researchers, with different experiences on AVR measurement, evaluated the 3D ultrasonographic AVR of the 29 patients (55 curves; coronal Cobb angle: 26.9 ± 11.3°). The gold standard AVR was determined from the 3D reconstruction of coronal and sagittal EOS radiographs. Intra-class correlation coefficients (ICCs), mean absolute difference (MAD), standard error measurements (SEM), and Bland-Altman's bias were reported to evaluate the intra-operator and inter-operator/rater reliabilities of 3D ultrasonography. The reliability of 3D ultrasonographic AVR measurements was further validated using inter-method with that of EOS.

RESULTS

ICCs for intra-operator and inter-operator/rater reliability assessment were all greater than 0.95. MAD, SEM, and bias for the 3D ultrasonographic AVRs were no more than 2.2°, 2.0°, and 0.5°, respectively. AVRs between both modalities were strongly correlated (R 2 = 0.901) and not significantly different (p = 0.205). Bland-Altman plot also shows that the bias was less than 1°, with no proportional bias between the difference and mean of expected and radiographic Cobb angles.

CONCLUSION

This study demonstrates that 3D ultrasonography is valid and reliable to evaluate AVR in AIS patients. 3D ultrasonography can be a potential tool for screening and following up subjects with AIS and evaluating the effectiveness of nonsurgical treatments.

Для цитирования: Lee Tin Yan, Yang De, Lai Kelly Ka-Lee, Castelein Rene M, Schlosser Tom P C, Chu Winnie, Lam Tsz-Ping, Zheng Yong-Ping. Three-dimensional ultrasonography could be a potential non-ionizing tool to evaluate vertebral rotation of subjects with adolescent idiopathic scoliosis.. JOR spine. 2023. DOI: 10.1002/jsp2.1259.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.