MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1140/epjp/s13360-022-02995-y

Медицинская библиотека · Urology journal · 2015

The Effect of Valsalva Leak Point Pressure on Outcomes of the Needleless ®System in Female Stress Urinary Incontinence.

Han Seung Bum, Kim Joon Chul, Lee Dong Hwan, Kim Hyo Sin, Koh Jun Sung, Hur Won Sok, Cho Kang Jun

СтатьяПеревод пока не подготовлен

Аннотация

OBJECTIVE

To evaluate the efficacy and safety of self-expanding metallic stents after insertion into the canine ureter.

MATERIALS AND

METHODS

Actively expanding metallic (Nitinol) stents (diameter 8-10 mm, length 4-6 cm) were placed in eight mongrel dogs (18-34 kg). Under general anaesthesia, a midline abdominal incision was made and a stent inserted directly into the ureter through a small incision; each animal was stented on one side. The dogs were assessed after 6 or 19 days or 2, 5 (two), 6 (two) and 7 months. Ureteric specimens were evaluated both macroscopically and microscopically.

RESULTS

Macroscopically there was no leakage of urine in any of the animals. On day 6 the inserted stent was patent despite blood clots in the mesh. The lumen was smooth and shiny in three dogs examined at 5, 6 and 7 months. One of the two dogs assessed at both 5 and 6 months had hydronephrosis associated with papillary hyper-epithelialization inside the stent, while the other animals had no dilatation of the renal pelvis. Microscopically there was loss of epithelium and bleeding of the ureteric wall at 6 days. Epithelial regeneration started after 19 days and was complete in the lumen at 2 months, with the stent incorporated into the wall of the ureter. Epithelialization was maintained up to 7 months, after which the problem of urothelial hyperplasia persisted, but an adequate lumen was maintained by epithelial regeneration. This epithelium was smooth and shiny, and composed of thin layers of cells.

CONCLUSION

Self-expanding metallic stents may be effective if hyperplastic epithelialization does not occur, as the stent was epithelialized within 2 months and the regenerated epithelium maintained for up to 7 months. Metallic stents may be useful for treating patients with renal failure caused by ureteric stenosis from malignant tumours.

Для цитирования: Han Seung Bum, Kim Joon Chul, Lee Dong Hwan, Kim Hyo Sin, Koh Jun Sung, Hur Won Sok, Cho Kang Jun. The Effect of Valsalva Leak Point Pressure on Outcomes of the Needleless ®System in Female Stress Urinary Incontinence.. Urology journal. 2015. DOI: 10.1140/epjp/s13360-022-02995-y.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.