MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/radadv/umag004

Медицинская библиотека · Radiology advances · 2026

nnUnet-based automated quantification of wrist joint synovitis volume in patients with rheumatoid arthritis: a feasibility study.

Zhou Bingjing, Wu Su, Griffith James Francis, Xiao Fan, Zhang Miaoru, Fukuda Takeshi, Tam Lai-Shan

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Synovitis is the key inflammatory feature of rheumatoid arthritis (RA). Quantitative assessment of synovitis better correlates with patient outcomes than semiquantitative assessment but it is time-consuming.

PURPOSE: To develop and validate an automated model for segmentation and quantification of wrist synovial tissue volume on postcontrast fat-suppressed T1-weighted MRI.

MATERIAL AND

METHODS

Patients with early RA (symptoms for ≤24 months) at a single center were recruited at baseline and were followed up at year 1 and year 8. Postcontrast axial fat-suppressed T1-weighted images of the most symptomatic wrist were acquired at 3.0 T. One observer manually segmented consecutive synovitis areas on all MRI datasets. A framework, based on the convolutional neural network, nnU-Net, was trained and validated (5-fold cross-validation with image level splits) with 295 image datasets used for model training and validation. The rheumatoid arthritis MRI score was used to semiquantitatively grade synovitis. Manually segmented synovial volume by a single reader was used as the reference standard. Forty-five external image datasets from 2 different imaging centers were used to test generalizable applicability.

RESULTS

For automated synovitis segmentation, the overall Sørensen-Dice similarity coefficient (DSC) was 0.75 ± 0.11 (mean ± SD) compared to manual segmentation. Higher DSC values were found in patients with moderate (0.80 ± 0.06) and severe (0.84 ± 0.05) degrees of synovitis. The model had a similar performance with externally acquired data (DSC value: 0.70 ± 0.20). Predicted and manually segmented synovitis volume measurements showed excellent agreement (Pearson correlation: r = 0.975, P < .001).

CONCLUSION

A fully automated model quantified wrist synovial tissue volume with good agreement to manual reference and maintained performance on external data, supporting potential use in clinical studies and prospective evaluation in practice.

Для цитирования: Zhou Bingjing, Wu Su, Griffith James Francis, Xiao Fan, Zhang Miaoru, Fukuda Takeshi, Tam Lai-Shan. nnUnet-based automated quantification of wrist joint synovitis volume in patients with rheumatoid arthritis: a feasibility study.. Radiology advances. 2026. DOI: 10.1093/radadv/umag004.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.