MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2460/javma.246.12.1339

Медицинская библиотека · Journal of the American Veterinary Medical Association · 2015

Characteristics of bone fractures and usefulness of micro-computed tomography for fracture detection in rabbits: 210 cases (2007-2013).

Sasai Hiroshi, Fujita Daisuke, Tagami Yukari, Seto Eiko, Denda Yuki, Hamakita Hideaki, Ichihashi Tomonori, Okamura Kensaku, Furuya Masaru, Tani Hiroyuki, Sasai Kazumi, Yamate Jyoji

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

To characterize bone fractures and the usefulness of micro-CT for imaging fractures in pet rabbits.

DESIGN

Retrospective case series.

ANIMALS: 210 client-owned rabbits with bone fractures.

PROCEDURES: Medical records of rabbits evaluated for bone fractures from 2007 through 2013 were examined. Information was collected on signalment and nature of fractures, and radiographic and micro-CT images of fractures were reviewed.

RESULTS

Almost half (n = 95 [47.7%]) of fractures were in rabbits < 3 years old. Accidental fall was the most common cause. Vertebral fracture was the most common type of fracture with a nonneoplastic cause (n = 46 [23.2%]) and was most common in the L4-L7 region. The tibia was the most common site for limb fracture among all fractures with a nonneoplastic cause (45 [22.7%]). Twelve (5.7%) fractures had a neoplastic cause, and 7 of these were associated with metastatic uterine adenocarcinoma. Females were significantly more likely to have a fracture caused by neoplasia than were males. Compared with radiography, micro-CT provided more detailed fracture information, particularly for complicated fractures or structures (eg, skull, pelvic, vertebral, and comminuted limb fractures).

CONCLUSIONS AND CLINICAL RELEVANCE: Findings were useful for understanding the nature of fractures in pet rabbits and supported the use of micro-CT versus radiography for fracture detection and evaluation.

Для цитирования: Sasai Hiroshi, Fujita Daisuke, Tagami Yukari, Seto Eiko, Denda Yuki, Hamakita Hideaki, Ichihashi Tomonori, Okamura Kensaku, Furuya Masaru, Tani Hiroyuki, Sasai Kazumi, Yamate Jyoji. Characteristics of bone fractures and usefulness of micro-computed tomography for fracture detection in rabbits: 210 cases (2007-2013).. Journal of the American Veterinary Medical Association. 2015. DOI: 10.2460/javma.246.12.1339.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.