Finite element analysis of dynamic changes in spinal mechanics of osteoporotic lumbar fracture.

Yan J, Liao Z, Yu Y

Перевод в очереди

Аннотация

AIM: This study aims to explore the effects of finite element biomechanical properties of different methods in the treatment of osteoporotic thoracolumbar fractures.

METHODS

Based on the ultra-thin computed tomography scan data of a volunteer's thoracolumbar spine, the finite element method was used to simulate the treatment of osteoporotic thoracolumbar fracture. Spiral computed tomography scanning was used to obtain images of the thoracolumbar region, which was then imported into Mimics software to obtain the three-dimensional geometric model. The finite element model of normal T11 - L2 segment was established by finite element software Abaqus and the validity of the model loading was verified. The finite element model of T11 vertebral compression fracture was established based on normal raw data. The clinical overextension reduction manipulation was simulated by different treatment methods and the changes in stress and displacement in different parts of injured vertebrae were analyzed.

RESULTS

An effective finite element model of T11-L2 segment was established. The maximum stress, axial compression strength, axial compression stiffness, and transverse shear stiffness were significantly better in the percutaneous kyphoplasty and percutaneous vertebroplasty treatment group than in the conservative treatment group and open treatment group (P < 0.05). Additionally, there was no significant difference between the open treatment group and conservative treatment group, or between the PKP and PVP treatment group.

CONCLUSION

Percutaneous vertebroplasty and percutaneous kyphoplasty not only met the requirements of normal functional kinematics of thoracolumbar spine, but also restored the stability of thoracolumbar spine. They had good biomechanical properties and remarkable application effects. The application of finite element analysis can help select a scientific, reasonable, and effective treatment scheme for the clinical diagnosis and treatment of osteoporotic thoracolumbar fractures.

Для цитирования: Yan J, Liao Z, Yu Y. Finite element analysis of dynamic changes in spinal mechanics of osteoporotic lumbar fracture.. European journal of medical research. 2022. DOI: 10.1186/s40001-022-00769-x.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.