MedElevator Войти в исследования
← Поиск публикаций

DOI 10.2106/jbjs.25.00621

Медицинская библиотека · The Journal of bone and joint surgery. American volume · 2025

Comparison of Highly Cross-Linked and Conventional Polyethylene During Simultaneous Bilateral Cruciate-Retaining Total Knee Arthroplasties: Results at a Minimum Follow-up of 15 Years.

Kim Young-Hoo, Park Jang-Won, Jang Young-Soo, Kim Eun-Jung

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

BACKGROUND

There have been no long-term studies comparing the revision rates of a highly cross-linked polyethylene (HXLPE) bearing with those of a conventional polyethylene (CP) bearing among cruciate-retaining (CR) total knee arthroplasties (TKAs). The aim of the current long-term study was to compare CR TKAs with HXLPE and CP bearings in terms of clinical, radiographic, and computed tomographic (CT) scan results; prevalence of osteolysis; revision rate; and implant survivorship.

METHODS

This study enrolled a consecutive series of 410 Korean patients (mean age, 62.6 ± 8 years) who underwent simultaneous bilateral TKAs during the same anesthetic session. This study included 164 men and 246 women. Each patient underwent a posterior CR high-flexion TKA (NexGen CR-Flex TKA; Zimmer Biomet) with an HXLPE bearing on 1 side and a NexGen CR-Flex TKA with a CP bearing on the opposite side. The mean follow-up period was 17.5 years (range, 15 to 19 years).

RESULTS

At the latest follow-up, there were no significant differences between the HXLPE and CP groups with regard to the Knee Society score (94 compared with 93 points), Western Ontario and McMaster Universities Osteoarthritis Index (19.2 points for both groups), range of motion (125° compared with 126°), radiographic and CT results, or revision rate (2.0% compared with 2.2%). No knee showed osteolysis in either group. The estimated survival rate at 17.5 years, using revision or aseptic loosening as the end point, was 98.0% (95% confidence interval, 92% to 100%) for the group with the CR-Flex TKA with an HXLPE bearing and 97.8% (95% confidence interval, 92% to 100%) for the group with the CR-Flex TKA with a CP bearing.

CONCLUSIONS

The findings of this long-term study (minimum follow-up of 15 years) indicate that CR-Flex TKAs with HXLPE and CP bearings both yielded excellent clinical outcomes and implant survivorship. However, no significant clinical advantage was observed for HXLPE over CP bearings in this patient population.

LEVEL OF EVIDENCE: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.

Для цитирования: Kim Young-Hoo, Park Jang-Won, Jang Young-Soo, Kim Eun-Jung. Comparison of Highly Cross-Linked and Conventional Polyethylene During Simultaneous Bilateral Cruciate-Retaining Total Knee Arthroplasties: Results at a Minimum Follow-up of 15 Years.. The Journal of bone and joint surgery. American volume. 2025. DOI: 10.2106/jbjs.25.00621.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.