m+Medelevator.RU
← Поиск публикаций
The spine journal : official journal of the North American Spine Society · 2026

Automated measurement of cervical sagittal and local parameters using a generalizable deep learning model: a multinational development and validation study.

СтатьяНаблюдательное исследованиеВалидационное исследованиеМногоцентровое исследованиеНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Kang Dong-Ho, Park Se-Jun, Park Jin-Sung, Park Jaeseok, Lee Chong-Suh

Аннотация

BACKGROUND CONTEXT: Manual measurement of cervical sagittal parameters is time-consuming and exhibits significant interobserver variability. Existing artificial intelligence models fail when C7 is obscured by shoulder anatomy.

PURPOSE: To develop and externally validate a deep learning model for automated cervical alignment measurements under clinical conditions, including C7-obscured cases.

DESIGN: Retrospective observational study.

PATIENT SAMPLE: A total of 5,604 lateral cervical radiographs were obtained from Chinese and Korean institutions.

OUTCOME MEASURE: Intraclass correlation coefficient (ICC), Pearson correlation (r), and Bland-Altman agreement.

METHODS: A Keypoint R-CNN with ResNet-50-FPN backbone was trained using multinational data, including C7-obscured cases. Model outputs were compared to consensus expert annotations using ICC, Pearson correlation, and Bland-Altman analysis. An independent dataset was used for external validation.

RESULTS: In the external validation set (n=100), 62 patients (62.0%) had a partially obscured C7 and 20 patients (20.0%) had a fully obscured C7. The final model showed excellent reliability for the C2-C7 lordosis (ICC=0.95, r=0.95), C2 slope (ICC=0.99, r=0.99) and C7 slope (ICC=0.91, r=0.91). The mean errors for these parameters were clinically negligible at -0.44°, 0.06°, and -0.38°, respectively. The reliability for all disc height measurements were excellent in internal test set (ICC=0.97-0.99). Measurement errors slightly increased in few patients with complete C7 obscuration.

CONCLUSION: The Keypoint R-CNN model enables rapid, accurate, and clinically generalizable automated cervical alignment measurements; however, C7 obscuration remains a critical limitation that requires targeted improvement.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты