MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/09544119261467211

Медицинская библиотека · Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine · 2026

Biomechanical effects of structural optimization on the ball-and-socket lumbar artificial disc: A finite element study.

Yan Jiahao, Guan Linyi, Li Yongsheng, Jin Tianrong, Chen Yanze, Xiang Dingding

СтатьяПеревод в очереди

Аннотация

Lumbar disc degeneration is a major contributor to low back pain and disability. Lumbar total disc replacement (LTDR) has been introduced as a motion-preserving alternative to spinal fusion, and its biomechanical performance is strongly influenced by prosthesis geometry. This study investigated the effects of two key geometric parameters, curvature radius and radial clearance, on the biomechanical behavior of a ball-and-socket LTDR. Three-dimensional finite element models of the L3-L5 lumbar spine were developed, incorporating prostheses with curvature radii ranging from 7 to 10 mm and radial clearances from 0.1 to 0.3 mm. Segmental range of motion (ROM) and adjacent intervertebral disc biomechanics were evaluated under physiological loading conditions. Increasing curvature radius substantially reduced flexion and lateral bending ROM while producing radius-dependent effects on axial rotation. It also led to elevated annulus fibrosus (AF) von Mises stress across all motion modes. Nucleus pulposus (NP) von Mises stress and strain increased modestly during flexion and lateral bending but decreased during axial rotation. Total deformation of both NP and AF decreased progressively. In contrast, increasing radial clearance moderately enhanced flexion and lateral bending ROM while producing negligible changes in stress and slightly modulating strain and total deformation. These results indicate that prosthesis geometry plays a key role in modulating spinal kinematics and adjacent segment loading following lumbar total disc replacement. Curvature radius exerts a stronger influence than radial clearance, which mainly serves as a secondary parameter for fine-tuning segmental motion.

Для цитирования: Yan Jiahao, Guan Linyi, Li Yongsheng, Jin Tianrong, Chen Yanze, Xiang Dingding. Biomechanical effects of structural optimization on the ball-and-socket lumbar artificial disc: A finite element study.. Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine. 2026. DOI: 10.1177/09544119261467211.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.