Endoscopic extruded screw removal after anterior cervical disc fusion: technical case report.

Lee Wha-Joon, Sheehan Jonas M, Stack Brendan C

Клинический случайСтатьяПеревод в очереди

Аннотация

OBJECTIVE AND

IMPORTANCE

Symptomatic complications related to screw migration and extrusion after anterior cervical disc fusion are uncommon.

CLINICAL PRESENTATION: We report a case of significant dysphagia owing to late screw migration.

INTERVENTION: An endoscopic transpharyngeal removal was performed without pharyngeal closure and with relief of symptoms.

CONCLUSION

A transpharyngeal endoscopic approach to remove loose anterior cervical hardware is feasible and warrants further evaluation.