MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jse.2022.08.004

Медицинская библиотека · Journal of shoulder and elbow surgery · 2022

The role of the lateral collateral ligament-capsule complex of the elbow under gravity varus.

Kwak Jae-Man, Rotman Dani, Lievano Jorge Rojas, Fitzsimmons James S, O'Driscoll Shawn W

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The lateral collateral ligament complex along with the capsule is likely to be at risk during arthroscopic extensor carpi radialis brevis release for lateral epicondylitis. We hypothesized that disruption of the lateral collateral ligament-capsule complex (LCL-cc) would increase the mean contact pressure on the coronoid under gravity varus.

MATERIALS AND

METHODS

Eight cadaveric elbows were tested via gravity varus and weighted varus (2 Nm) stress tests using a custom-made machine designed to simulate muscle loads while allowing passive flexion of the elbow. Mean articular surface contact pressure data were collected and processed using intra-articular thin-film sensors and software. Sequential testing was performed on each specimen from stage 0 to stage 3 (stage 0, intact; stage 1, release of anterior one-third of LCL-cc; stage 2; release of anterior two-thirds of LCL-cc; and stage 3, release of entire LCL-cc). The mean contact pressure on the coronoid and the mean ratio of contact pressure on the medial coronoid to that on the lateral coronoid (M/L ratio) were used for comparisons among the stages and the intact elbow.

RESULTS

The overall mean contact pressure significantly increased in stage 2 (P = .0004 in gravity varus and P = .0001 in weighted varus) and stage 3 (P < .0001 in gravity varus and P < .0001 in weighted varus) compared with that in stage 0. In contrast, release of the anterior one-third of the LCL-cc (stage 1) did not significantly increase the mean contact pressure on the coronoid in any degree of flexion under gravity varus (P = .09) or weighted varus loading (P = .6). The M/L ratio difference between stage 0 and stage 1 was 1.1 ± 1.1 under gravity varus (P = .8) and 2.1 ± 1.0 under weighted varus (P = .2). The overall M/L ratios in stage 2 and stage 3 were significantly higher than those seen in stage 0 under gravity varus (P = .04 in stage 2 and P = .02 in stage 3) and weighted varus (P = .006 in stage 2 and P < .0001 in stage 3).

CONCLUSIONS

Loss of the anterior two-thirds or more of the LCL-cc significantly increases the overall mean contact pressure on the coronoid, especially the medial coronoid, under both gravity varus and weighted varus. The LCL-cc also plays a role in the distribution of coronoid contact pressure against gravity varus loads.

Для цитирования: Kwak Jae-Man, Rotman Dani, Lievano Jorge Rojas, Fitzsimmons James S, O'Driscoll Shawn W. The role of the lateral collateral ligament-capsule complex of the elbow under gravity varus.. Journal of shoulder and elbow surgery. 2022. DOI: 10.1016/j.jse.2022.08.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.