MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.clim.2023.109270

Медицинская библиотека · Clinical immunology (Orlando, Fla.) · 2023

The dynamics of laboratory markers reflecting cytokine overproduction in macrophage activation syndrome complicated with systemic juvenile idiopathic arthritis.

Kaneko Shuya, Shimizu Masaki, Miyaoka Futaba, Shimbo Asami, Irabu Hitoshi, Mizuta Mao, Nakagishi Yasuo, Iwata Naomi, Fujimura Junya, Mori Masaaki, Morio Tomohiro

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVES

To validate the correlation between laboratory markers reflecting disease activity of macrophage activation syndrome (MAS) and serum cytokine levels and identify the valuable laboratory markers that change over time for a prompt MAS diagnosis.

METHODS

Serum cytokine levels were determined by enzyme-linked immunosorbent assay and compared with laboratory markers reflecting MAS disease activity.The changes in values were evaluated from the acute phase of systemic juvenile idiopathic arthritis (s-JIA) to MAS diagnosis.

RESULTS

CXCL9 was significantly correlated with aspartate aminotransferase (AST), lactate dehydrogenase (LDH), D dimer, and urine β2 microglobulin levels. sTNF-RII was significantly correlated with platelet counts, AST, LDH, D dimer, and ferritin levels. Significant changes in platelet count, LDH, and D dimer levels were observed. Decreased platelet counts were the most valuable indicator for MAS diagnosis.

CONCLUSION

Monitoring the laboratory markers that change over time, particularly decreased platelet counts, was valuable for the prompt MAS diagnosis in s-JIA.

Для цитирования: Kaneko Shuya, Shimizu Masaki, Miyaoka Futaba, Shimbo Asami, Irabu Hitoshi, Mizuta Mao, Nakagishi Yasuo, Iwata Naomi, Fujimura Junya, Mori Masaaki, Morio Tomohiro. The dynamics of laboratory markers reflecting cytokine overproduction in macrophage activation syndrome complicated with systemic juvenile idiopathic arthritis.. Clinical immunology (Orlando, Fla.). 2023. DOI: 10.1016/j.clim.2023.109270.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.