MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/bsd.0000000000001850

Медицинская библиотека · Clinical spine surgery · 2025

Effect of Screw Thread Pitch, Purchase Depth, and Trajectory on Cervical Lateral Mass Fixation Strength.

Abuhantash Monther, Mulhall Drew, Gustafson Sara, Goytan Michael

СтатьяПеревод в очереди

Аннотация

STUDY

DESIGN

Biomechanical study.

OBJECTIVE

Determine the effect of screw thread pitch, trajectory, and purchase depth on the screw pull-out strength in lateral mass fixation constructs.

SUMMARY OF BACKGROUND DATA: Fusion of the cervical spine is routinely performed with lateral mass screw fixation. It is imperative to optimize the lateral mass fixation construct strength to minimize the risk of hardware failure and subsequent complications and reoperations.

METHODS

Biomechanical testing was performed using bicortical artificial bone models to replicate the lateral mass of the cervical spine. Cortical and cancellous screws of 3.5 mm diameter were compared at 3 purchase depths: unicortical, bicortical, and bicortical backed-out to unicortical, and 2 trajectories: Roy-Camille (RC) and Magerl. In a second construct, bicortical 3.5 mm screws were replaced with unicortical 4.0 mm screws. Both thread pitches and trajectories were also compared.

RESULTS

Fixation with the RC technique was stronger than with Magerl in all constructs. Roy-Camille fixation using cortical screws was stronger than cancellous screws in all purchase depths. Magerl fixation using cancellous screws was stronger in all purchase depths but only statistically significant for the group where the bicortical screw was backed-out to unicortical.The construct where the bicortical 3.5 mm screw was replaced with a 4.0 mm unicortical screw was stronger than when the screw was backed-out to a unicortical depth. This was significant for cortical screws in both trajectories but only significant for cancellous screws using the RC technique.

CONCLUSIONS

Biomechanical strength of cervical lateral mass fixation was shown to be directly influenced by thread pitch, depth, and trajectory. Thus, spine surgeons should be cognizant of their fixation constructs and any changes made to their components.

Для цитирования: Abuhantash Monther, Mulhall Drew, Gustafson Sara, Goytan Michael. Effect of Screw Thread Pitch, Purchase Depth, and Trajectory on Cervical Lateral Mass Fixation Strength.. Clinical spine surgery. 2025. DOI: 10.1097/bsd.0000000000001850.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.