Mid-term outcomes of the R3™ delta ceramic acetabular system in total hip arthroplasty.

Davis Edward T, Remes Ville, Virolainen Petri, Gebuhr Peter, Van Backlé Bart, Revell Matthew P, Kopjar Branko

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Whilst bony fixation of hip replacement has stable solutions, there remains controversy over which bearing best optimizes longevity and function. Ceramic-on-ceramic (CoC) bearing combinations are associated with lower risk of revision due to aseptic loosening and dislocation. Evidence for long-term functional outcomes of modern, 4th generation CoC bearings is limited. The aim of this study was to analyze outcomes and complications of the R3™ Acetabular System (Smith & Nephew, Inc., Cordova, TN, USA) in combination with BIOLOX® Delta ceramic femoral head in patients undergoing primary total hip arthroplasty (THA).

METHODS

Between June 2009 and May 2011, 175 patients (178 hips) were enrolled into a prospective, study at 6 sites in Europe and prospectively followed-up at 3 months and 1, 3, 5, and 7 years postoperative.

RESULTS

Total WOMAC score improved from 63 (range, 22-91) preoperative to 8 (range, 0-8) at 1-year follow-up and remained unchanged at 7-year follow-up. Modified Harris hip score improved from 45 (range, 10-87) preoperative to 83 (range, 25-100) at 3 months, 91 (range, 42-100) at 1 year, and 92 (range, 46, 100) at 7 years. UCLA Activity Rating Scale score improved from 3.3 (range, 1-8) preoperative to 6.2 (range, 2-8) at 1 year; it marginally declined to 5.8 (range, 3-8) at 7-year follow-up. There were 4 trochanteric fractures and 5 patients died of unrelated reasons. Three hips were revised (2 periprosthetic fractures and 1 subluxation). The 7-year cumulative survival rate was 98.3%.

CONCLUSION

Clinical and functional improvements of THA with CoC bearing are maintained at 7 years postoperative.

TRIAL REGISTRATION: ClinicalTrials.Gov, NCT03566082 , Registered 10 January 2018-retrospectively registered.

Для цитирования: Davis Edward T, Remes Ville, Virolainen Petri, Gebuhr Peter, Van Backlé Bart, Revell Matthew P, Kopjar Branko. Mid-term outcomes of the R3™ delta ceramic acetabular system in total hip arthroplasty.. Journal of orthopaedic surgery and research. 2021. DOI: 10.1186/s13018-020-02192-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.