MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jstrokecerebrovasdis.2016.09.017

Медицинская библиотека · Journal of stroke and cerebrovascular diseases : the official journal of National Stroke Association · 2016

T1-Weighted Magnetic Resonance Carotid Plaque Imaging: a Comparison between Conventional and Fast Spin-Echo Techniques.

Narumi Shinsuke, Sasaki Makoto, Miyazawa Haruna, Natori Tatsunori, Ito Kohei, Ogasawara Kuniaki, Kobayashi Masakazu, Hitomi Jiro, Terayama Yasuo

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

BACKGROUND

Magnetic resonance imaging is widely used to evaluate the intraplaque components of the cervical carotid artery. The non-gated T1-weighted spin-echo (SE) technique has been reported to have an excellent ability for discriminating stable and unstable plaques. However, the diagnostic performance of various SE-based techniques remains unclear. Hence, we compared plaque signals obtained by 3 kinds of SE-based methods with histological findings.

METHODS

We prospectively examined 40 patients who underwent carotid endarterectomy by using 1.5-T scanners and obtained 2-dimensional (2D) conventional spin-echo (CSE), 2D fast spin-echo (FSE), and 3-dimensional (3D)-FSE images with identical repetition times. We calculated contrast ratios (CRs) of the plaques against adjacent muscles and compared these values with the pathological classification of the specimens.

RESULTS

The CRs of type VII-VIII (calcific/fibrous), IV-V (lipid-rich/necrotic), and VI (complex/hemorrhagic) plaques were significantly different between all the methods (P <.001) and were discriminated from each other at sensitivities of 83%-100% and specificities of 94%-100%. The CRs of type IV-V plaques significantly differed between the methods (low to high, 2D-FSE, 2D-CSE, and 3D-FSE; P <.05); those of the type VI plaques were significantly lower with the 2D-FSE method than with the other methods (P <.01).

CONCLUSIONS

The SE-based T1-weighted images can readily discriminate plaque characteristics with high sensitivities and specificities, although the signal intensity of unstable plaques was significantly high on the 3D-FSE images and significantly low on the 2D-FSE images.

Для цитирования: Narumi Shinsuke, Sasaki Makoto, Miyazawa Haruna, Natori Tatsunori, Ito Kohei, Ogasawara Kuniaki, Kobayashi Masakazu, Hitomi Jiro, Terayama Yasuo. T1-Weighted Magnetic Resonance Carotid Plaque Imaging: a Comparison between Conventional and Fast Spin-Echo Techniques.. Journal of stroke and cerebrovascular diseases : the official journal of National Stroke Association. 2016. DOI: 10.1016/j.jstrokecerebrovasdis.2016.09.017.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.