MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.cca.2013.05.011

Медицинская библиотека · Clinica chimica acta; international journal of clinical chemistry · 2013

Clinical performance evaluation of a novel rapid response chemiluminescent immunoassay for the detection of autoantibodies to extractable nuclear antigens.

Bentow Chelsea, Swart Andreas, Wu Jason, Seaman Andrea, Manfredi Mariangela, Infantino Maria, Benucci Maurizio, Lakos Gabriella, Mahler Michael

СтатьяПеревод в очереди

Аннотация

BACKGROUND

We analyzed the performance of a novel ENA screening chemiluminescent immunoassay (CIA) and the confirmation QUANTA Flash tests.

METHODS

Sera (n=1079) from patients referred to a rheumatology clinic were screened by QUANTA Flash ENA7 (INOVA Diagnostics). All positive (n=89) and a matched control group (n=90) were reflexed for autoantibodies to the individual antigens. Moreover, sera from patients with systemic lupus erythematosus (SLE, n=252), systemic sclerosis (SSc, n=64), polymyositis/dermatomyositis (PM/DM, n=72), Sjögren's syndrome (SjS, n=39) as well as disease controls (n=605) were tested by ENA7 CIA and by Quanta Lite ENA6 ELISA (INOVA).

RESULTS

89/1079 (8.3%) samples were ENA7 CIA positive with the following reactivity profile: RNP (36.0%), Sm (13.5%), Scl-70 (9.0%), Jo-1 (0.0%), Ro60 (44.9%), Ro52 (39.3%) and SS-B (24.7%). In the negative group, the reactivity profile was: RNP (1.1%), Sm (1.1%), Scl-70 (2.2%) and 0.0% for Jo-1, Ro60, Ro52 and SS-B. The positive/negative/total agreements (ENA7 CIA vs. confirmation assays) were 95.3%/91.5%/93.3%. The sensitivity of the ENA7 CIA was 62.3% in SLE, 54.7% in SSc, 92.3% in SjS, 50.0% in PM/DM, and 61.8% in the total systemic autoimmune rheumatic disease (SARD) population (specificity 95.0%).

CONCLUSION

The QUANTA Flash ENA7 CIA is a reliable screening test.

Для цитирования: Bentow Chelsea, Swart Andreas, Wu Jason, Seaman Andrea, Manfredi Mariangela, Infantino Maria, Benucci Maurizio, Lakos Gabriella, Mahler Michael. Clinical performance evaluation of a novel rapid response chemiluminescent immunoassay for the detection of autoantibodies to extractable nuclear antigens.. Clinica chimica acta; international journal of clinical chemistry. 2013. DOI: 10.1016/j.cca.2013.05.011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.