MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jhsa.2022.02.011

Медицинская библиотека · The Journal of hand surgery · 2022

Defining the Digit-Specific Confluence of the A1 Pulley.

Hevesi Mario, Logli Anthony L, Ramazanian Taghi, Kakar Sanjeev

СтатьяПеревод в очереди

Аннотация

PURPOSE: Variations in the description of the flexor pulley system exist, particularly in whether the A1 and A2 pulleys represent discrete or confluent entities. This has potentially important clinical relevance at the time of A1 pulley release for symptomatic trigger finger, given the goal of adequate release without overrelease. The purpose of this study was to determine the relative prevalence of confluent A1 pulleys on a digit-by-digit basis employing 2.5× loupes alone, thereby simulating a clinical surgical environment.

METHODS

Cadaveric anatomic specimens underwent flexor pulley system dissection under 2.5× loupe magnification by 2 hand surgeons. The presence of pulley confluence and length (measured from the proximal aspect to the distal aspect) was recorded and compared on a digit-to-digit basis.

RESULTS

Forty-five digits, comprising 9 adult forearm or hand specimens (5 right and 4 left) obtained from 6 donors (4 men and 2 women, age: 67 ± 8 years), were dissected. A total of 19 confluent A1 pulleys were encountered, with notable digit-by-digit variation in the prevalence of confluent pulleys. There were 0 confluent pulleys observed in the thumb, compared with 6 confluent pulleys observed in the middle finger. The average overall A1 pulley length was 5.0 ± 1.5 mm, with a similar pulley length observed between the digits.

CONCLUSIONS

A1 pulley confluence varies on a digit-to-digit basis, with no observed confluence in the thumb and the most common confluence observed in the middle finger.

CLINICAL RELEVANCE: In the setting of intraoperatively observed pulley confluence, we suggest pulley release under traction in order to develop the plane between the A1 and A2 pulleys and, thus, confirm the complete and isolated release of the A1 pulley.

Для цитирования: Hevesi Mario, Logli Anthony L, Ramazanian Taghi, Kakar Sanjeev. Defining the Digit-Specific Confluence of the A1 Pulley.. The Journal of hand surgery. 2022. DOI: 10.1016/j.jhsa.2022.02.011.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.