DOI 10.1186/s13018-021-02818-3
The morphological mapping of lateral compression type 1 pelvic fracture and pelvic ring stability classification: a finite element analysis.
Аннотация
PURPOSE: This finite element analysis assessed lateral compression (LC-1) fracture stability using machine learning for morphological mapping and classification of pelvic ring stability.
METHODS
Computed tomography (CT) files of LC-1 pelvic fractures were collected. After morphological mapping and producing matrix data, we used K-means clustering in unsupervised machine learning to classify the fractures. Based on these subtypes, we manually added fracture lines in ANSYS software. Finally, we performed a finite element analysis of a normal pelvis and eight fracture subtypes based on von Mises stress and total deformation changes.
RESULTS
A total of 218 consecutive cases were analyzed. According to the three main factors-zone of sacral injury and completion, pubic ramus injury side, and the sagittal rotation of the injured hemipelvis-the LC-1 injuries were classified into eight subtypes (I-VIII). No significant differences in stress or deformation were observed between unilateral and bilateral public ramus fractures. Subtypes VI and VIII showed the maximum stress while subtypes V-VIII showed the maximum deformation in the total pelvis and sacrum. The subtypes did not differ in superior public ramus deformation.
CONCLUSIONS
Complete fracture of sacrum zones 2/3 may be a feature of unstable LC-1 fractures. Surgeons should give surgical strategies for subtypes V-VIII.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.