MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00586-025-09634-x

Медицинская библиотека · European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2025

Old technique, new applications: can the H-reflex be a possible real-time indicator in endoscopic surgery for decompression of acute disc herniation at the S1 root?

Rodrigues Carvalho Marta, Caldas Marques Vitor, Pinto Soares Baldomero, Pokorny Gabriel, Pedro Thiego, Bringel Mario, Grion Rodrigo

СтатьяКлинический случайПеревод в очереди

Аннотация

BACKGROUND

The Hoffmann (H-) reflex is a monosynaptic electrophysiological response that reflects S1-root integrity. Although widely used in experimental and in clinical outpatient neurophysiological testing, its intra-operative application during endoscopic lumbar surgery is rarely reported. We present the first real-time documentation of H-reflex normalization immediately after endoscopic decompression of an acute L5-S1 disc herniation.

CASE DESCRIPTION: A 49-year-old woman presented with acute right-sided S1 radiculopathy (ankle dorsiflexion/plantar-flexion MRC grade III; hallux extension grade I). MRI showed a large, right sub-articular L5-S1 disc extrusion compressing the S1 nerve root. Unilateral biportal endoscopic discectomy was performed under general anesthesia with multimodal intra-operative neuromonitoring (MEPs, free-run EMG, and continuous tibial-nerve H-reflex). Baseline recordings revealed marked side-to-side asymmetry: right-leg MEP amplitudes were depressed, and the right H-reflex was low and unstable. During foraminoplasty and fragment removal, a sudden, sustained 100% surge in right H-reflex amplitude occurred, coincidence with root decompression, while MEPs remained unchanged. Free-run EMG discharges abated after the H-reflex improved. Post-operative recovery was uneventful. At 2 months the patient demonstrated near-complete motor recovery (MRC IV-V) and full pain relief.

CONCLUSION

Continuous H-reflex monitoring provided an immediate, sensitive marker of S1-root decompression when conventional MEPs failed to reflect functional recovery. This single-case experience supports the feasibility and potential prognostic value of adding H-reflex surveillance to the neuromonitoring toolkit for endoscopic lumbar surgery. Prospective studies in larger cohorts are warranted to validate threshold criteria, refine stimulation parameters, and determine cost-effectiveness.

Для цитирования: Rodrigues Carvalho Marta, Caldas Marques Vitor, Pinto Soares Baldomero, Pokorny Gabriel, Pedro Thiego, Bringel Mario, Grion Rodrigo. Old technique, new applications: can the H-reflex be a possible real-time indicator in endoscopic surgery for decompression of acute disc herniation at the S1 root?. European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society. 2025. DOI: 10.1007/s00586-025-09634-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.