Component gap measurement reflects the planned gap balance during total knee arthroplasty more accurately and reliably than bone surface gap measurement.

Shin Kyun-Ho, Jang Ki-Mo, Han Seung-Beom

СтатьяПеревод в очереди

Аннотация

PURPOSE: This study aimed to compare the reliability of two gap assessment methods (component and bone surface gap measurement vs. planned gap balance) and identify the contributors to component gaps other than planned gaps.

METHODS

The prospectively collected data for 122 consecutive primary total knee arthroplasties (TKAs; 114 patients). After femoral planning for gap balancing, the medial and lateral planned gaps were calculated (planned gap). The established medial extension and flexion gaps (MEG and MFG, respectively) and lateral extension and flexion gaps (LEG and LFG, respectively) were measured with and without the TKA components (bone surface and component gaps) at 0° and 90° flexion. The intraclass and Pearson correlation coefficients for each gap measurement method were assessed using planned gap values, and multiple linear regression analyses were performed to identify the contributors to component gaps.

RESULTS

Compared with the bone surface gap measurement, the component gap measurement showed higher reliability and stronger correlation with the planned gap balance for each gap. The changes in the medial posterior femoral offset contributed to the MEG and LEG, whereas those in the joint line height contributed to the LEG. The changes in the hip-knee-ankle angle and lateral posterior femoral offset contributed to the LFG.

CONCLUSION

Component gap measurements of the established gap more accurately and reliably reflect the planned gap balance than do bone surface gap measurements. The established gaps are affected by several factors other than femoral planning.

Для цитирования: Shin Kyun-Ho, Jang Ki-Mo, Han Seung-Beom. Component gap measurement reflects the planned gap balance during total knee arthroplasty more accurately and reliably than bone surface gap measurement.. Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA. 2020. DOI: 10.1007/s00167-020-06324-7.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.