MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.fas.2016.08.008

Медицинская библиотека · Foot and ankle surgery : official journal of the European Society of Foot and Ankle Surgeons · 2016

A prospective 24 months follow-up of a three component press-fit prosthesis for hallux rigidus.

Wassink S, Burger B J, Saragas N P, Asunción Márquez J, Trtik L, Harlaar J

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The aim of this study was to evaluate the results following total first metatarsophalangeal (FMTP) joint replacement arthroplasty using a modular three component press fit prosthesis at two year follow up.

METHODS

All patient data was collected in a prospective way in four study centres. Both preoperative and postoperative evaluation consisted of an assessment using the AOFAS-HMI score, visual analogue scale for pain, evaluation of the range of motion and patient satisfaction scores. Postoperative X-rays were reviewed for loosening and radiolucency up to two years.

RESULTS

Fifty-five feet were available for analysis at 24 months. Two implants were removed during the study. Six more feet had additional surgery due to stiffness or malalignment. Postoperative AOFAS-HMI scores improved significantly by 32.4 points at two year follow-up (p<0.001). The visual analogue scale for pain improved significantly from 6.8 (std 1,6) preoperatively to 1.6 (std 1,9) postoperatively (p<0.0001). Mean dorsiflexion improved from 12.6 (std 10,1) degrees preoperatively to 31.2 (std 16,8) degrees postoperatively. Eighty-seven percent of patients were moderately to well satisfied with the end result. Eighteen prostheses showed radiolucency at 24 months.

CONCLUSION

Implantation of a Metis® modular three component press fit prosthesis for the metatarsophalangeal joint in hallux rigidus shows significant improvement in AOFAS-HMI scores and a decrease in pain. Concerns remain with regard to early reoperation rate (14.5%) and long term survival of the implant. Future studies will have to address these aspects.

Для цитирования: Wassink S, Burger B J, Saragas N P, Asunción Márquez J, Trtik L, Harlaar J. A prospective 24 months follow-up of a three component press-fit prosthesis for hallux rigidus.. Foot and ankle surgery : official journal of the European Society of Foot and Ankle Surgeons. 2016. DOI: 10.1016/j.fas.2016.08.008.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.