DOI 10.1016/j.jspd.2017.10.001

Медицинская библиотека · Spine deformity · 2018

Inter- and Intraobserver Reliability of Pelvic Obliquity Measurement Methods in Patients With Cerebral Palsy.

Shrader M Wade, Andrisevic Emily M, Belthur Mohan V, White Gregory R, Boan Carla, Wood William

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

STUDY

DESIGN

Retrospective, chart review.

OBJECTIVES

The identification and management of pelvic obliquity in neuromuscular scoliosis can be difficult; therefore, appropriate evaluation of this pathology is important. Variations in presentation have resulted in various methods of measurement, without a consensus or gold standard measurement. This study is the evaluation of reliability of five methods commonly used to determine pelvic obliquity in the frontal plane.

SUMMARY OF BACKGROUND DATA: Previous studies have used five different methods (ie, the Maloney method, the O'Brien method, the Osebold method, the Allen and Ferguson method, and the Lindseth method) to determine pelvic obliquity in the frontal plane.

METHODS

Radiographic images of 50 patients with neuromuscular scoliosis involving the pelvic girdle were identified and evaluated by a team of 5 raters. Each rater was instructed to apply five commonly used methods of measuring pelvic obliquity. The same raters were asked to rate the same radiographs again after a minimum of one month. The interobserver reliability was assessed using the intraclass correlation coefficient (ICC) and the intraobserver analysis was assessed using the Pearson correlation. A rating greater than 0.8 was considered excellent reliability.

RESULTS

The Maloney method showing the highest interobserver reliability of ICC of 0.965 and 0.964. The Lindseth method had the lowest ICC, but all the methods were considered highly reliable by the rating classification system. The Maloney method also showed the highest intraobserver reliability, ranging from 0.845 to 0.962. The Allen and Ferguson method had the lowest intraobserver reliability.

CONCLUSIONS

Many of the methods tested had excellent reliability in this study, but our data suggest the Maloney method is the most reliable method of measuring pelvic obliquity on a frontal view radiograph.

LEVEL OF EVIDENCE: Level III, retrospective, comparative study.

Для цитирования: Shrader M Wade, Andrisevic Emily M, Belthur Mohan V, White Gregory R, Boan Carla, Wood William. Inter- and Intraobserver Reliability of Pelvic Obliquity Measurement Methods in Patients With Cerebral Palsy.. Spine deformity. 2018. DOI: 10.1016/j.jspd.2017.10.001.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.