MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00296-018-4164-4

Медицинская библиотека · Rheumatology international · 2018

Is ultrasonographic enthesitis evaluation helpful for diagnosis of non-radiographic axial spondyloarthritis?

Ozsoy-Unubol Tugba, Yagci Ilker

СтатьяПеревод в очереди

Аннотация

The aim of this study is to evaluate the diagnostic utility of ultrasonographic enthesitis assessment in patients with non-radiographic axial spondyloarthritis (nr-axSpA) and to compare different sonographic scoring methods. Patients with nr-axSpA (n = 30) and mechanical back pain (MBP) (n = 30) were enrolled in the study with standardized clinical criteria. For both of the groups, a total of 18 entheses were evaluated in each patient with B mode ultrasound and power Doppler by a sonographer who is blinded to initial clinical and radiological assessments. Glasgow Ultrasound Enthesitis Scoring System (GUESS), Madrid Sonographic Enthesitis Index (MASEI) and D'Agostino grading system were performed. Intra-rater and inter-rater reliability analyses were evaluated with the intraclass correlation coefficient (ICC). There was at least one enthesitis in 96.7% of patients with nr-axSpA. Median values of the number of enthesitis were 5 in nr-axSpA and 0 in MBP. Mean GUESS total scores were 0.9 in MBP and 4.5 in nr-axSpA. Mean MASEI total scores were 2.3 and 10.5, respectively. The sensitivities were 96.7% and 93.3% for GUESS and MASEI while the detected specificities were 80% for both methods. For Intra-rater reliability analysis, ICC was calculated as 0.981 for GUESS and 0.975 for MASEI, while it was calculated as 0.964 and 0.962 for inter-rater reliability analysis. Thus, evaluation of enthesitis with ultrasound is a reliable, helpful tool for the distinction of patients with nr-axSpA from patients with MBP. We favored the use of MASEI because of assessing upper extremity, using power Doppler and having a correlation with disease activity.

Для цитирования: Ozsoy-Unubol Tugba, Yagci Ilker. Is ultrasonographic enthesitis evaluation helpful for diagnosis of non-radiographic axial spondyloarthritis?. Rheumatology international. 2018. DOI: 10.1007/s00296-018-4164-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.