Biomechanical comparison of inverted triangle and L-shaped screw configurations with medial buttress and anteromedial support plate in Pauwels type III femoral neck fractures.

Erem Murat, Demirtaş Utku, Yıldırım Savaş, Selçuk Eşref, Çopuroğlu Cem

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

INTRODUCTION

Surgical stabilization of Pauwels Type III femoral neck fractures remains a significant challenge due to high vertical shear forces. While the medial buttress plate is a recognized solution, it requires extensive deep dissection. This study aims to compare the biomechanical performance of various screw configurations combined with either a medial buttress or anteromedial support plate.

MATERIALS AND

METHODS

Twenty-five third-generation synthetic femurs were used to create a standardized 70-degree (Pauwels III) fracture model. Specimens were divided into five groups (n = 5): (A) Inverted triangle (IT) screws with a Pauwels screw, (B) Inverted triangle (IT) with medial buttress plate (MBP), (C) Inverted triangle with anteromedial support plate (ASP), (D) L-configuration with medial buttress plate (MBP), and (E) L-configuration with anteromedial support plate (ASP). Axial loading was applied at 2 mm/min until construct failure, defined objectively by the real-time force-distance curve.

RESULTS

Although no statistically significant difference was found between groups (p = 0.102), a large effect size was observed (η² = 0.309). Group C (IT + ASP) demonstrated the highest mean failure load (1695 ± 494.6 N). Conversely, Group E (L-configuration + ASP) exhibited the lowest stability (977.2 ± 195.4 N) with a remarkably narrow standard deviation. The majority of failures occurred as transverse subtrochanteric fractures distal to the implants.

CONCLUSION

The combination of an inverted triangle screw arrangement with an anteromedial support plate demonstrated comparable biomechanical stability to the medial buttress plate, while offering a potentially safer surgical corridor. Conversely, pairing L-shaped screw configurations with anteromedial support plates resulted in the lowest mean ultimate load-to-failure among the tested constructs, likely due to potential stress riser effects.

Для цитирования: Erem Murat, Demirtaş Utku, Yıldırım Savaş, Selçuk Eşref, Çopuroğlu Cem. Biomechanical comparison of inverted triangle and L-shaped screw configurations with medial buttress and anteromedial support plate in Pauwels type III femoral neck fractures.. Archives of orthopaedic and trauma surgery. 2026. DOI: 10.1007/s00402-026-06352-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.