MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/idr18020023

Медицинская библиотека · Infectious disease reports · 2026

Mycobacterium fortuitum: A Neglected Cause of Culture-Negative Prosthetic Valve Endocarditis and a Literature Review.

Şahin Selen, Tümkaya Kılınç İrem, Yüksel Eda, Mehmet Çağla, Dinç Bedia, Alp Meşe Emine

Клинический случайСтатьяПеревод в очереди

Аннотация

BACKGROUND/

OBJECTIVES

Prosthetic valve endocarditis caused by non-tuberculous mycobacteria is a rare but serious condition and is often associated with delayed diagnosis due to initially negative routine blood cultures with late positivity after prolonged incubation. Mycobacterium fortuitum, a rapidly growing mycobacterium, is an uncommon cause of endocarditis but may result in significant morbidity if not promptly identified.

METHODS

We report a 67-year-old man with prior cardiac surgery who presented 18 months later with recurrent fever, weight loss, and renal dysfunction. Initial blood cultures, echocardiography, and standard imaging were non-diagnostic. Ongoing clinical suspicion prompted extended mycobacterial cultures with prolonged incubation and molecular identification performed at a reference laboratory, which revealed M. fortuitum.

RESULTS

Antimicrobial susceptibility testing demonstrated susceptibility to amikacin, ciprofloxacin, and clarithromycin, and treatment was initiated with an amikacin-based combination regimen. The patient showed marked clinical and laboratory improvement, including resolution of fever and stabilization of renal function.

CONCLUSIONS

This case highlights the diagnostic and therapeutic challenges of M. fortuitum prosthetic valve endocarditis and underscores the limitations of routine diagnostic methods in culture-negative endocarditis. It also emphasizes the importance of prolonged incubation and targeted microbiological workflows in suspected cases.

Для цитирования: Şahin Selen, Tümkaya Kılınç İrem, Yüksel Eda, Mehmet Çağla, Dinç Bedia, Alp Meşe Emine. Mycobacterium fortuitum: A Neglected Cause of Culture-Negative Prosthetic Valve Endocarditis and a Literature Review.. Infectious disease reports. 2026. DOI: 10.3390/idr18020023.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.