MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.clinbiomech.2024.106235

Медицинская библиотека · Clinical biomechanics (Bristol, Avon) · 2024

Primary stability in locking plate fixation for proximal humeral fractures may be increased by using an additional nail osteosynthesis in combination with locking plate osteosynthesis-A biomechanical comparison.

Schöbel Tobias, Gemkow Maximilian, Wendler Toni, Schleifenbaum Stefan, Löffler Sabine, Theopold Jan, Hepp Pierre

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Stability is regarded as an important factor for proper healing and avoiding secondary dislocation in osteoporotic fractures of the proximal humerus. Several surgical techniques have been proposed for treatment, including intramedullary nail osteosynthesis and locking plate fixation. This study introduces a novel approach that combines both techniques and compares its primary stability with conventional methods.

METHODS

The study involved 25 osteoporotic humeri with two-part fracture models, which were randomly assigned to locking-plate fixation, intramedullary nailing, or a combination of both techniques. The specimens were subjected to sinusoidal loading at 250 N in 20° abduction for 5000 cycles and then to quasi-static loading until failure. Fracture movement, failure mode, and failure load were measured and compared among the groups.

FINDINGS: The groups fixated with intramedullary nailing and the groups fixated with intramedullary nailing and locking plate fixation showed significantly lower fracture motion than the group using locking plate fixation only (p < 0.005) and significantly higher load to failure (p = 0.007 and p = 0.0062, respectively). There was no significant difference between the group using intramedullary nailing and the group using locking-plate fixation and intramedullary nailing in fracture movement or load-to-failure (p > 0.005).

INTERPRETATION: The results indicate that locking plate fixation provides less primary stability than intramedullary nailing or the combined of both techniques. This combined approach may offer advantages as a treatment for complex proximal humeral fractures in osteoporotic bone, and specific implants should be developed to ensure optimal treatment.

Для цитирования: Schöbel Tobias, Gemkow Maximilian, Wendler Toni, Schleifenbaum Stefan, Löffler Sabine, Theopold Jan, Hepp Pierre. Primary stability in locking plate fixation for proximal humeral fractures may be increased by using an additional nail osteosynthesis in combination with locking plate osteosynthesis-A biomechanical comparison.. Clinical biomechanics (Bristol, Avon). 2024. DOI: 10.1016/j.clinbiomech.2024.106235.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.