Empirical Modelling Workflow for Resolution Invariant Assessment of Osteophytes.

Durongbhan Pholpat, Davey Catherine E, Stok Kathryn S

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

Traditional quantitative analysis of bone microstructure in micro-computed tomography (microCT) is dependent on animal scale and requires parametric tuning in new implementations. This study aims to develop an automated and resolution-invariant 3D image processing workflow for quantitative assessment of osteophytes.

METHODS

In this workflow, cortical bone was segmented from microCT scans, and a 3D sphere-fitting transform was performed to obtain a thickness map, for which each voxel is assigned a thickness value corresponding to the size of the largest sphere containing the voxel that fits entirely within the cortical bone. From the thickness map, a 1-voxel thick outer surface was extracted to model surface roughness. The thickness values of the outer surface were empirically estimated by a series of known statistical distributions. Resulting parameters describing best-fit distributions, along with other cortical bone metrics, were analysed to determine sensitivity to osteoarthritis and the presence of osteophytes.

RESULTS

The workflow was validated using microCT scans and histological gradings of rabbit and rat tibiofemoral joints. Visual inspection shows that samples with osteoarthritis and the presence of osteophytes have more surface voxels assigned small thickness values. The distribution of surface thickness values for each animal is best described by Gamma distributions, whose shape parameter is consistently sensitive to osteoarthritis and the presence of osteophytes.

CONCLUSION

Combining traditional image processing with empirical distribution fitting provides an automated, objective, and resolution-invariant workflow for osteophyte assessment.

SIGNIFICANCE: The proposed method is simple, yet elegant in its implementation, and can be readily used in new implementations.

Для цитирования: Durongbhan Pholpat, Davey Catherine E, Stok Kathryn S. Empirical Modelling Workflow for Resolution Invariant Assessment of Osteophytes.. IEEE transactions on bio-medical engineering. 2024. DOI: 10.1109/tbme.2024.3431634.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.