Comparison of quantitative radiomorphometric predictors of healthy and MRONJ-affected bone using panoramic radiography and cone-beam CT.

Aslan Elif, Onem Erinc, Mert Ali, Baksi B Guniz

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

OBJECTIVES

To determine the most distinctive quantitative radiomorphometric parameter(s) for the detection of MRONJ-affected bone changes in panoramic radiography (PR) and cone-beam CT (CBCT).

METHODS

PR and sagittal CBCT slices of 24 MRONJ patients and 22 healthy controls were used for the measurements of mandibular cortical thickness (MCT), fractal dimension (FD), lacunarity, mean gray value (MGV), bone area fraction (BA/TA), trabecular thickness (Tb.Th), trabecular separation (Tb.Sp), trabecular number (Tb.N). MCT was measured in the mental foramen region. While FD and lacunarity were measured on mandibular trabecular and cortical regions-of-interest (ROIs), the remaining parameters were measured on trabecular ROIs. The independent samples t-test was used to compare the measurements between the MRONJ and control groups for both imaging modalities (P = .05).

RESULTS

MCT was the only parameter that differentiated MRONJ-affected bone in both PR and CBCT (P < .05). None of the remaining parameters revealed any difference for MRONJ-affected bone in CBCT (P > .05). FD, lacunarity, MGV, BA/TA, and Tb.Sp could distinguish MRONJ-affected trabecular bone in PR (P < .05). The correspondent ROI for both imaging methods that was reliable for detecting MRONJ-affected bone was the trabecular bone distal to the mental foramen above the inferior alveolar canal (ROI-3).

CONCLUSIONS

MCT is a reliable parameter for the discrimination of MRONJ-affected bone in both PR and CBCT images. PR may be used to detect MRONJ-affected trabecular bone using FD, lacunarity, MGV, BA/TA, and Tb.Sp measurements as well.

Для цитирования: Aslan Elif, Onem Erinc, Mert Ali, Baksi B Guniz. Comparison of quantitative radiomorphometric predictors of healthy and MRONJ-affected bone using panoramic radiography and cone-beam CT.. Dento maxillo facial radiology. 2024. DOI: 10.1093/dmfr/twae024.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.