MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.recot.2025.04.007

Медицинская библиотека · Revista espanola de cirugia ortopedica y traumatologia · 2025

[Translated article] Surgical treatment of non-displaced subcapital hip fracture: Femoral Neck System vs. cannulated screws. Comparative study.

Lalueza-Andreu P, Martínez-García Á, Checa-Betegón P, García-Coiradas J, Valle-Cruz J A, Marco-Martínez F

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

OBJECTIVE

The objective of this study is to compare the outcomes of using the Femoral Neck System (FNS) (DePuy Synthes®) versus the use of cannulated screws (CS) in the surgical treatment of non-displaced subcapital hip fractures.

MATERIALS AND

METHODS

A retrospective cohort study was conducted on non-displaced subcapital hip fractures treated with CS or FNS between 2020 and 2023, with a minimum follow-up of one year. A total of 28 patients were included, 14 treated with CS and 14 with FNS. Demographic, radiological, clinical, and functional variables were analyzed.

RESULTS

In the CS group, 64% were male, with a mean age of 66.5 years (SD 14.9) and an average follow-up of 22 months (range, 12-36 months). In the FNS group, 57% were male, with a median age of 60.8 years (SD 13.78) and an average follow-up of 16 months (range, 12-24 months). Regarding functional outcomes, no significant differences were found between FNS and CS in the Harris scale: 94.21 ± 11.55 for FNS and 96.50 ± 6.9 for CS (p = 0.618). The total postoperative complications (FNS/CS) were 7.1% versus 43%, and implant failure with conversion to total hip replacement was 0% versus 43%, both significantly higher in the CS group (p = 0.047; p = 0.016, respectively). The FNS also presented a lower rate of avascular necrosis (0% versus 11.1%, p = 0.391) and nonunion (0% versus 20%, p = 0.163), although these differences did not reach statistical significance.

CONCLUSIONS

Although both treatment methods, cannulated screws and the FNS, showed similar short-term functional outcomes in the management of undisplaced subcapital femoral fractures, the FNS demonstrated a significantly lower rate of complications and reoperations. These results suggest that the FNS could be considered a safer and more effective option compared to cannulated screws.

Для цитирования: Lalueza-Andreu P, Martínez-García Á, Checa-Betegón P, García-Coiradas J, Valle-Cruz J A, Marco-Martínez F. [Translated article] Surgical treatment of non-displaced subcapital hip fracture: Femoral Neck System vs. cannulated screws. Comparative study.. Revista espanola de cirugia ortopedica y traumatologia. 2025. DOI: 10.1016/j.recot.2025.04.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.