Excessive Heat Generation by Power-Driven Craniotomy Tools: A Possible Cause of Autologous Bone Flap Resorption Observed in an Ex Vivo Simulation.

Shimizu Satoru, Koizumi Hiroyuki, Shibahara Ichiyo, Kumabe Toshihiro

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Bone flap resorption is an issue after autologous cranioplasty. Critical temperatures above 50°C generated by power-driven craniotomy tools may lead to thermal osteonecrosis, a possible factor in resorption. This ex vivo study examined whether the tools produced excessive heat resulting in bone flap resorption.

METHODS

Using swine scapulae maintained at body temperature, burr holes, straight and curved cuts, and wire-pass holes were made with power-driven craniotomy tools. Drilling was at the conventional feed rate (FR) plus irrigation (FR-I+), at a high FR plus irrigation (hFR-I+), and at high FR without irrigation (hFR-I-). The temperature in each trial was recorded by an infrared thermographic camera.

RESULTS

With FR-I+, the maximum temperature at the burr holes, the cuts, and the wire-pass holes was 69.0°C, 56.7°C, and 46.2°C, respectively. With hFR-I+, these temperatures were 53.1°C, 52.1°C, and 46.0°C, with hFR-I- they were 56.0°C, 66.5°C, and 50.0°C; hFR-I- burr hole- and cutting procedures resulted in the highest incidence of bone temperatures above 50°C followed by FR-I+, and hFR-I+. At the site of wire-pass holes, only hFR-I- drilling produced this temperature.

CONCLUSIONS

Except during prolonged procedures in thick bones, most drilling with irrigation did not reach the critical temperature. Drilling without irrigation risked generating the critical temperature. Knowing those characteristics may be a help to perform craniotomy with less thermal bone damage.

Для цитирования: Shimizu Satoru, Koizumi Hiroyuki, Shibahara Ichiyo, Kumabe Toshihiro. Excessive Heat Generation by Power-Driven Craniotomy Tools: A Possible Cause of Autologous Bone Flap Resorption Observed in an Ex Vivo Simulation.. World neurosurgery. 2024. DOI: 10.1016/j.wneu.2024.05.010.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.