MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/2325967118807176

Медицинская библиотека · Orthopaedic journal of sports medicine · 2018

The Cliff Sign: A New Radiographic Sign of Hip Instability.

Packer Jonathan D, Cowan James B, Rebolledo Brian J, Shibata Kotaro R, Riley Geoffrey M, Finlay Andrea K, Safran Marc R

СтатьяПеревод в очереди

Аннотация

BACKGROUND

The preoperative diagnosis of hip microinstability is challenging. Although physical examination maneuvers and magnetic resonance imaging findings associated with microinstability have been described, there are limited reports of radiographic features. In patients with microinstability, we observed a high incidence of a steep drop-off on the lateral edge of the femoral head, which we have named the "cliff sign."

PURPOSE: (1) To determine the relationship of the cliff sign and associated measurements with intraoperative microinstability and (2) to determine the interobserver reliability of these measurements.

STUDY

DESIGN

Cohort study (diagnosis); Level of evidence, 2.

METHODS

A total of 115 consecutive patients who underwent hip arthroscopy were identified. Patients with prior hip surgery, Legg-Calve-Perthes disease, fractures, pigmented villonodular synovitis, or synovial chondromatosis were excluded, resulting in the inclusion of 96 patients in the study. A perfect circle around the femoral head was created on anteroposterior pelvis radiographs. If the lateral femoral head did not completely fill the perfect circle, it was considered a positive cliff sign. Five additional measurements relating to the cliff sign were calculated. The diagnosis of microinstability was made intraoperatively by the (1) amount of traction required to distract the hip, (2) lack of hip reduction after initial traction release following joint venting, or (3) intraoperative findings consistent with hip microinstability. Continuous variables were analyzed through use of unpaired t tests and discrete variables with Fisher exact tests. Interobserver reliability (n = 3) was determined for each measurement.

RESULTS

Overall, 89% (39/44) of patients with microinstability had a cliff sign, compared with 27% of patients (14/52) without instability (P < .0001). Conversely, 74% of patients with a cliff sign had microinstability, while only 12% of patients without a cliff sign had instability (P < .0001). In women younger than 32 years with a cliff sign, 100% (20/20) were diagnosed with instability. No differences were found in any of the 5 additional measurements. Excellent interobserver reliability was found for the presence of a cliff sign and the cliff angle measurement.

CONCLUSION

We have identified a radiographic finding, the cliff sign, that is associated with the intraoperative diagnosis of hip microinstability and has excellent interobserver reliability. Results showed that 100% of young women with a cliff sign had intraoperative microinstability. The cliff sign may be useful in the preoperative diagnosis of hip microinstability.

Для цитирования: Packer Jonathan D, Cowan James B, Rebolledo Brian J, Shibata Kotaro R, Riley Geoffrey M, Finlay Andrea K, Safran Marc R. The Cliff Sign: A New Radiographic Sign of Hip Instability.. Orthopaedic journal of sports medicine. 2018. DOI: 10.1177/2325967118807176.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.