DOI 10.1097/bsd.0000000000001809
Computed Tomography Assessment of Long-Term Fusion and Subsidence for Anterior Lumbar Interbody Fusion Performed at the Lumbosacral Junction.
Аннотация
STUDY
DESIGN
Retrospective cohort study.
OBJECTIVE
To evaluate factors associated with long-term pseudoarthrosis and subsidence following L5-S1 anterior lumbar interbody fusion (ALIF).
SUMMARY OF BACKGROUND DATA: Reported fusion rates for ALIF at the lumbosacral junction vary widely.
METHODS
Patients undergoing L5-S1 ALIF (November 1, 2016-September 3, 2021) were retrospectively analyzed. Fusion (Bridwell grades: 1-2) or pseudoarthrosis (Bridwell grades: 3-4) and subsidence (Marchi grades: 0-3) were determined using 1-year follow-up computed tomography (CT) studies.
RESULTS
Overall, 101 patients were analyzed [mean (SD) age, 62.8 (13.3) y; 51 (50.5%) men]. Bone morphogenic protein (BMP) was used in 59 patients (58.4%), demineralized bone matrix in 44 (43.6%), and cellular allograft in 57 (56.4%). Oswestry Disability Index and Short-Form 36 scores improved postoperatively ( P ≤0.01). At L5-S1, 79 patients (78.2%) had fusion at 1 year. Patients receiving 3D-printed porous [89.5% (17/19)] and solid titanium [100% (14/14)] interbody cages were significantly more likely to have fusion than those receiving polyetheretherketone [70.6% (48/68)] interbody cages ( P =0.02). Adjusted multivariate analyses found that titanium interbody cages were associated with fusion (odds ratio=5.42, P =0.04). Patients with subsidence [n=17 (16.8%)] were significantly older than patients without subsidence [n=84 (83.2%)]: 70.2 (4.7) years vs. 61.3 (14.0) years ( P <0.001).
CONCLUSIONS
The 1-year postoperative CT findings showed that 78.2% of the cohort achieved fusion. Fusion was more common among patients with 3D-printed and solid titanium implants than among those with polyetheretherketone implants. Subsidence was more common among older patients. No differences in fusion or subsidence were found based on surgical indication, allograft type, or other patient characteristics.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.