MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jhsa.2021.04.033

Медицинская библиотека · The Journal of hand surgery · 2021

Sonographic Location of Distal A1 Pulley by Means of a Bony Acoustic Landmark on the Proximal Phalanx: An Anatomic Study.

Jurbala Brian, Burbank Troy

СтатьяПеревод в очереди

Аннотация

PURPOSE: To identify the anatomic relationship between the distal extent of the A1 pulley and the distalmost insertion point of the palmar plate into the base of the proximal phalanx at a metaphyseal bony ridge, the "P1 peak" (P1P), which is a bony acoustic landmark easily identifiable on sonography of the finger.

METHODS

We studied 48 fingers (no thumbs) from 12 fresh frozen cadavers with high-resolution ultrasound. A 20-gauge hypodermic needle was directed perpendicular to the long axis of the tendon sheath along a plumb line drawn at the level of the bony flare of the proximal metaphyseal-diaphyseal junction of the proximal phalanx, or the P1P, under high-resolution ultrasound guidance. Dissection was then performed, and the distance of the needle barrel and the actual distance of the P1P from the distal edge of the A1 pulley were recorded.

RESULTS

The study demonstrated that accurate placement of the needle within 1 mm of the actual P1P was possible using ultrasound guidance and that the P1P was within 1 mm of the distal edge of the actual A1 pulley in all specimens studied.

CONCLUSIONS

In all the specimens studied, we found that the P1P may be used as a clearly identifiable sonographic reference landmark to identify the distal extent of the A1 pulley.

CLINICAL RELEVANCE: Using the P1P landmark as a guide to judge the completeness of ultrasound-guided percutaneous trigger finger release may reduce the risks of incomplete distal release and inadvertent release of the A2 pulley.

Для цитирования: Jurbala Brian, Burbank Troy. Sonographic Location of Distal A1 Pulley by Means of a Bony Acoustic Landmark on the Proximal Phalanx: An Anatomic Study.. The Journal of hand surgery. 2021. DOI: 10.1016/j.jhsa.2021.04.033.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.