BACKGROUND

This study aimed to investigate the short-term complications (minimum 1-year follow-up) after either an arthroscopic Bristow or Latarjet procedure for anterior shoulder instability utilizing screw or suture-button fixation.

METHODS

Patients undergoing arthroscopic Bristow or Latarjet procedures between November 2016 and April 2021 were enrolled. Data were collected at baseline, 3 months, 6 months, and every year after surgery. Risks of postoperative complications and unplanned reoperations were assessed. A multivariable regression model was used to identify risk factors for complications and to determine the association of complications with patient-reported outcomes.

RESULTS

A total of 412 patients (425 shoulders) undergoing arthroscopic Bristow or Latarjet procedures performed by a single surgeon between November 2016 and April 2021 were reviewed. Two hundred and ninety-nine patients (308 shoulders, 76.2% of 404 eligible) with a mean follow-up of 22.3 ± 4.2 months were included for analysis. Two hundred and sixty-nine shoulders (87.3%) underwent a Bristow procedure (165 with screw and 104 with suture-button fixation), while 39 (12.7%) underwent a Latarjet procedure (18 with screw and 21 with suture-button fixation). Eighty-two patients (83 shoulders) reported a total of 85 complications within 2 years after surgery, with an overall complication rate of 26.9%. The rates of recurrent dislocation or subluxation and infection were 1.9% and 0.6%, respectively, while a total of 4 (1.3%) of the shoulders had unplanned reoperations. The most common complications were graft-related (11.7%), followed by complications involving neurologic symptoms (10.7%). The overall, graft, and neurologic complication rates following Bristow or Latarjet procedures were 27.1% versus 25.6%, 12.3% versus 7.7%, and 10.0% versus 15.4%, respectively. Compared with the Bristow technique with screw fixation, Bristow with suture-button fixation yielded a lower risk of any complications (odds ratio [OR], 0.55; p = 0.04). Paying with rural insurance and poor sleep quality prior to surgery were associated with increased risk of any complications.

CONCLUSIONS

Compared with arthroscopic Bristow procedures with screw fixation, Bristow procedures with suture-button fixation resulted in a lower overall complication risk. Both patient demographic and implant-specific factors were associated with the development of a complication.

LEVEL OF EVIDENCE: Therapeutic Level II . See Instructions for Authors for a complete description of levels of evidence.

Для цитирования: Shao Zhenxing, Jiang Yanfang, Song Qingfa, Wang Hangle, Luo Hao, Cheng Xu, Cui Guoqing. Short-Term Complications of Arthroscopic Bristow or Latarjet Procedure with Screw Versus Suture-Button Fixation: A Prospective Study of 308 Consecutive Cases by a Single Surgeon.. The Journal of bone and joint surgery. American volume. 2024. DOI: 10.2106/jbjs.23.00390.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.