MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s40001-024-01737-3

Медицинская библиотека · European journal of medical research · 2024

Increasing the angle between caudal screw and the transverse plane may aggravate the risk of femoral head necrosis by deteriorating the fixation stability in patients with femoral neck fracture.

Zhang Jian, Wan Shengyu, Luo Xiaozhong, Zhang Caidong, Wu Chao, He Lipeng, Li Jingchi

СтатьяПеревод в очереди

Аннотация

Necrosis of the femoral head is the main complication in femoral neck fracture patients with triangle cannulated screw fixation. Instant postoperative fixation instability is a main reason for the higher risk of femoral head necrosis. Biomechanical studies have shown that cross screw fixation can effectively optimize fixation stability in patients with proximal humerus fractures and pedicle screw fixation, but whether this method can also effectively optimize the fixation stability of femoral neck fractures and reduce the corresponding risk of femoral head necrosis has yet to be identified. In this study, a retrospective review of imaging data in femoral neck fracture patients was performed. The cross angle between the femoral neck and the caudal cannulated screw was reported; if the angle between the screw and the transverse plane increased, it was recorded as positive; otherwise, it was recorded as negative. Angle values and their corresponding absolute values were compared in patients with and without femoral head necrosis. Regression analysis identified potential risk factors for femoral head necrosis. Moreover, the biomechanical effect of the screw-femoral neck angle on fixation stability was also verified by numerical mechanical simulations. Clinical review presented significantly larger positive angle values in patients with femoral head necrosis, which was also proven to be an independent risk factor for this complication. Moreover, fixation stability progressively deteriorated with increasing angle between the caudal screw and the transverse plane. Therefore, increasing the angle between the caudal screw and the transverse plane may aggravate the risk of femoral head necrosis by deteriorating the fixation stability in patients with femoral neck fracture.

Для цитирования: Zhang Jian, Wan Shengyu, Luo Xiaozhong, Zhang Caidong, Wu Chao, He Lipeng, Li Jingchi. Increasing the angle between caudal screw and the transverse plane may aggravate the risk of femoral head necrosis by deteriorating the fixation stability in patients with femoral neck fracture.. European journal of medical research. 2024. DOI: 10.1186/s40001-024-01737-3.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.