MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12903-026-08912-4

Медицинская библиотека · BMC oral health · 2026

Wear resistance and fracture strength of BioFlx, zirconia and stainless steel crowns for primary molars after thermomechanical aging: an in vitro comparative study.

Ateşçi Alp Abidin, Yılmaz Dilek Özge, Gergit Berk, Kılıç Münevver Çoruh, Şimşek Hüseyin

СтатьяСравнительное исследованиеПеревод в очереди

Аннотация

BACKGROUND

Full-coverage restorations are often required for primary molars with extensive carious destruction. Stainless steel crowns remain the long-standing reference, while prefabricated zirconia and polymer-based crowns have become tooth-colored alternatives. Direct comparisons under a single thermomechanical protocol, with separate wear and fracture cohorts, remain limited. This in vitro study quantified post-aging occlusal wear and compressive fracture load in four prefabricated crown systems for mandibular second primary molars.

METHODS

Eighty crowns were tested, with 10 specimens per material for each outcome: two prefabricated zirconia crowns, one polymer-based crown, and one stainless steel crown. Identical resin dies were 3D-printed and all crowns were luted with glass-ionomer cement. All specimens underwent 10,000 thermal cycles between 5 °C and 55 °C. The wear cohort underwent 150,000 chewing cycles at 50 N and 1.2 Hz, and wear was scored on a 0-3 scale by two blinded examiners. The fracture cohort was loaded to failure. Wear scores were compared using Kruskal-Wallis and Dunn-Bonferroni tests; fracture loads were analyzed using one-way ANOVA and Tukey HSD.

RESULTS

Mean wear scores were 1.1 ± 0.3 for NuSmile, 1.2 ± 0.4 for ProfZr, 1.7 ± 0.4 for SSC, and 2.2 ± 0.4 for BioFlx. The zirconia groups did not differ significantly (p = 0.68), whereas both showed lower wear scores than SSC (p = 0.04) and BioFlx (p = 0.01). SSC also showed lower wear scores than BioFlx (p = 0.03). Mean fracture loads were 3148.4 ± 643.4 N for BioFlx, 2703.4 ± 243.1 N for SSC, 1076.1 ± 186.9 N for NuSmile, and 565.5 ± 159.6 N for ProfZr (p < 0.001). BioFlx and SSC did not differ significantly (p = 0.093), while both exceeded the zirconia groups (p < 0.001). NuSmile exceeded ProfZr (p = 0.043).

CONCLUSIONS

Under this in vitro model, zirconia crowns showed the lowest wear scores, whereas BioFlx and SSC showed the highest fracture loads. Each material demonstrated a distinct mechanical profile. Laboratory rankings alone should not guide clinical recommendations; long-term clinical studies are needed.

Для цитирования: Ateşçi Alp Abidin, Yılmaz Dilek Özge, Gergit Berk, Kılıç Münevver Çoruh, Şimşek Hüseyin. Wear resistance and fracture strength of BioFlx, zirconia and stainless steel crowns for primary molars after thermomechanical aging: an in vitro comparative study.. BMC oral health. 2026. DOI: 10.1186/s12903-026-08912-4.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.