m+Medelevator.RU
← Поиск публикаций
BMC oral health · 2024

Stability of standardized uptake values for quantitative bone SPECT for jawbone lesions: a single-center cross-sectional study.

СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Hata Hironobu, Shimomura Satoshi, Imamachi Kenji, Sato Jun, Asaka Takuya, Hirata Kenji, Funayama Kyousuke, Mori Yoichi, Matsuzaka Masashi, Nambu Toshikazu, Kitagawa Yoshimasa

Аннотация

BACKGROUND: The long time required for bone uptake of radiopharmaceutical material after injection for bone scintigraphy is a burden for patients with poor health. Thus, to assess whether the uptake time could be reduced for single-photon emission computed tomography (SPECT) of the jawbone, this study evaluated differences in maximum standardized uptake values (SUVmax) within patients using SPECT imaging at 2 and 3 hours after radiopharmaceutical injection.

METHODS: A total of 33 patients undergoing treatment or in post-treatment follow-up for medication-related osteonecrosis of the jaw, who visited our hospital between July 2020 and August 2021 and could receive SPECT twice on the same day, were enrolled in the study. Patients were injected with technetium-99 m hydroxymethylene diphosphonate (Tc-99 m HMDP) intravenously. The SUVmax for healthy parietal bones and jawbone lesions were calculated from the SPECT images using quantitative analysis software, and the SUVmax were compared between 2- and 3-hour uptake times.

RESULTS: After exclusion, 30 patients were included in the study. In the 2-hour and 3-hour images, the median SUVmax of the parietal bones were 1.90 and 1.81, respectively, and those of the jawbone lesions were 9.25 and 9.39, respectively. The limits of agreement (LOA) ranged from - 0.33 to 0.25 in the parietal bones, and the %LOA ranged from - 9.8 to 17.3% in the jawbone lesions, showing high equivalence between the two uptake durations. The SUVmax showed no clinical differences between the 2- and 3-hour uptake durations for Tc-99 m HMDP SPECT of the jawbone.

CONCLUSIONS: The results of this study justify a 2-3-hour uptake window when performing quantitative SPECT of the jawbone. Therefore, the minimum uptake time can potentially be reduced to only 2 hours.

Предметные рубрики MeSH

ИП Урсолов Владлен Сергеевич

ИНН 500118482352 · ОГРНИП 314500117700049

Реквизиты и контакты