MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/230949901402200112

Медицинская библиотека · Journal of orthopaedic surgery (Hong Kong) · 2014

Flexible hinge silicone implant with or without titanium grommets for arthroplasty of the first metatarsophalangeal joint.

Kanzaki Noriyuki, Nishiyama Takayuki, Fujishiro Takaaki, Hayash Shinya, Hashimoto Shingo, Kuroda Ryosuke, Kurosaka Masahiro

СтатьяПеревод в очереди

Аннотация

PURPOSE: To review outcomes of 37 patients who underwent arthroplasty of the first metatarsophalangeal joint using flexible hinge silicone implants with or without titanium grommets.

METHODS

36 women and one man (63 feet) underwent arthroplasty of the first metatarsophalangeal joint for rheumatoid arthritis (RA) using Swanson flexible hinge silicone toe implants with or without titanium grommets. 20 women (35 feet) aged 31 to 72 (mean, 52) years with Steinbrocker grade II (n=4), grade III (n=6), and grade IV (n=10) RA of the feet were treated with the implant without grommets, whereas 16 women and one man (28 feet) aged 48 to 73 (mean, 60) years with Steinbrocker grade III (n=4) and grade IV (n=13) RA of the feet were treated with the implant with grommets. Pain levels were self-rated. Degenerative changes and the presence of osteophytes or deformity were recorded, as were breakage or deformation of the implants, radiolucencies around the implant, implant loosening, silicone-induced synovitis, and sclerosis around the implant.

RESULTS

All patients reported pain relief from severe to mild or moderate. Respectively for the feet with and without grommets, the rates of implant deformation were 25% and 63% (p=0.031), whereas the rates of moderate-to-severe radiolucencies (>2 mm) were 4% and 34% (p=0.004). Sclerosis developed around the implant in all feet.

CONCLUSION

Titanium grommets appear to protect the implant and improve clinical outcomes.

Для цитирования: Kanzaki Noriyuki, Nishiyama Takayuki, Fujishiro Takaaki, Hayash Shinya, Hashimoto Shingo, Kuroda Ryosuke, Kurosaka Masahiro. Flexible hinge silicone implant with or without titanium grommets for arthroplasty of the first metatarsophalangeal joint.. Journal of orthopaedic surgery (Hong Kong). 2014. DOI: 10.1177/230949901402200112.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.