STUDY

DESIGN

Experimental animal study.

OBJECTIVE

To investigate the osteogenic properties of a particulate uncalcined, unsintered hydroxyapatite/polydllactide (u-HA/PdlLA) composite scaffold loaded with bone marrow aspirate (BMA).

SUMMARY OF BACKGROUND DATA: Because of the high morbidity associated with bone graft harvesting, current research in spine surgery has largely focused on bone graft alternatives involving a combination of scaffolds and osteogenic substances. BMA is obtained by a simple and relatively noninvasive method and can easily be clinically applied as an osteogenic material. However, few studies have reported successful posterolateral spinal fusion (PLF) with BMA-loaded synthetic materials.

METHODS

Porous u-HA/PdlLA composites loaded with BMA were used as bone graft substitutes. In experiment 1, porous u-HA/PdlLA cylinders containing or lacking BMA were implanted in rabbit muscles. They were retrieved 4, 8, and 12 weeks after implantation, and ectopic bone formation was histologically evaluated. In experiment 2, 48 rabbits underwent PLF with 1 of 4 bone grafts: autogenous bone (group 1); single-strip u-HA/PdlLA alone (group 2); morselized u-HA/PdlLA + BMA (group 3); or single-strip u-HA/PdlLA + BMA (group 4). After 12 weeks, fusion was assessed by manual palpation, microcomputed tomography, mechanical tests, and histologic examination.

RESULTS

In experiment 1, ectopic bone formation was observed in BMA-loaded u-HA/PdlLA, and the new bone area increased until 12 weeks after implantation. In experiment 2, the fusion rates in groups 1, 2, 3, and 4 were 58.3%, 16.7%, 66.7%, and 91.7%, respectively, as determined by manual palpation, and 66.7%, 16.7%, 75.0%, and 91.7%, respectively, as determined by microcomputed tomography. The mechanical strength was significantly greater in group 4 than in the other groups (P < 0.05).

CONCLUSION

Conclusion. Our results indicate that BMA-loaded porous μ-HA/PdlLA is an effective alternative to autogenous bone grafts. The structure and composition of porous u-HA/PdlLA render it an effective scaffold for BMA.

Для цитирования: Tanaka Kojiro, Takemoto Mitsuru, Fujibayashi Shunsuke, Neo Masashi, Shikinami Yasuo, Nakamura Takashi. A bioactive and bioresorbable porous cubic composite scaffold loaded with bone marrow aspirate: a potential alternative to autogenous bone grafting.. Spine. 2011. DOI: 10.1097/brs.0b013e3181d39067.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.