MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s12879-023-08935-0

Медицинская библиотека · BMC infectious diseases · 2024

Diagnosis of human leptospirosis: systematic review and meta-analysis of the diagnostic accuracy of the Leptospira microscopic agglutination test, PCR targeting Lfb1, and IgM ELISA to Leptospira fainei serovar Hurstbridge.

Valente Marta, Bramugy Justina, Keddie Suzanne H, Hopkins Heidi, Bassat Quique, Baerenbold Oliver, Bradley John, Falconer Jane, Keogh Ruth H, Newton Paul N, Picardeau Mathieu, Crump John A

МетаанализСистематический обзорСтатьяПеревод в очереди

Аннотация

BACKGROUND

Leptospirosis is an underdiagnosed infectious disease with non-specific clinical presentation that requires laboratory confirmation for diagnosis. The serologic reference standard remains the microscopic agglutination test (MAT) on paired serum samples. However, reported estimates of MAT's sensitivity vary. We evaluated the accuracy of four index tests, MAT on paired samples as well as alternative standards for leptospirosis diagnosis: MAT on single acute-phase samples, polymerase chain reaction (PCR) with the target gene Lfb1, and ELISA IgM with Leptospira fainei serovar Hurstbridge as an antigen.

METHODS

We performed a systematic review of studies reporting results of leptospirosis diagnostic tests. We searched eight electronic databases and selected studies that tested human blood samples and compared index tests with blood culture and/or PCR and/or MAT (comparator tests). For MAT selection criteria we defined a threshold for single acute-phase samples according to a national classification of leptospirosis endemicity. We used a Bayesian random-effect meta-analysis to estimate the sensitivity and specificity of MAT in single acute-phase and paired samples separately, and assessed risk of bias using the Quality Assessment of Studies of Diagnostic Accuracy Approach- 2 (QUADAS-2) tool.

RESULTS

For the MAT accuracy evaluation, 15 studies were included, 11 with single acute-phase serum, and 12 with paired sera. Two included studies used PCR targeting the Lfb1 gene, and one included study used IgM ELISA with Leptospira fainei serovar Hurstbridge as antigen. For MAT in single acute-phase samples, the pooled sensitivity and specificity were 14% (95% credible interval [CrI] 3-38%) and 86% (95% CrI 59-96%), respectively, and the predicted sensitivity and specificity were 14% (95% CrI 0-90%) and 86% (95% CrI 9-100%). Among paired MAT samples, the pooled sensitivity and specificity were 68% (95% CrI 32-92%) and 75% (95% CrI 45-93%) respectively, and the predicted sensitivity and specificity were 69% (95% CrI 2-100%) and 75% (2-100%).

CONCLUSIONS

Based on our analysis, the accuracy of MAT in paired samples was not high, but it remains the reference standard until a more accurate diagnostic test is developed. Future studies that include larger numbers of participants with paired samples will improve the certainty of accuracy estimates.

Для цитирования: Valente Marta, Bramugy Justina, Keddie Suzanne H, Hopkins Heidi, Bassat Quique, Baerenbold Oliver, Bradley John, Falconer Jane, Keogh Ruth H, Newton Paul N, Picardeau Mathieu, Crump John A. Diagnosis of human leptospirosis: systematic review and meta-analysis of the diagnostic accuracy of the Leptospira microscopic agglutination test, PCR targeting Lfb1, and IgM ELISA to Leptospira fainei serovar Hurstbridge.. BMC infectious diseases. 2024. DOI: 10.1186/s12879-023-08935-0.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.