MedElevator Войти в исследования
← Поиск публикаций
Медицинская библиотека · Wiadomosci lekarskie (Warsaw, Poland : 1960) · 2020

Mathematical modeling of the stress-strain state of the "bone-implant" system during the osteosynthesis with a philos with polylactic acid implants.

Korzh Mykola O, Makarov Vasyl B, Lipovsky Volodymyr I, Morozenko Dmytro V, Danylchenko Svitlana I

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

The aim: To study was to use mathematical modeling in assessing the stress-strain state of the bone-implant system during plate osteosynthesis with a PHILOS plate of a proximal humerus fracture with polylactic acid implants.

PATIENTS AND

METHODS

Materials and methods: Two bone-implant systems with a three-fragment humerus fracture according to the Neer classification (type 11-C1 according to the AO / ASIF classification) were selected for the study, one of which was with additional reinforcement of the head fragment with two polylactic acid implants (PLA - polylactide Ingeo™ Biopolymer 4032D). Sawbones (Europe AB, Malmö, Sweden) built the humeral model on 3D scanning of the composite model № 3404 of the left humerus.

RESULTS

Results

A comparative analysis of the obtained results of mathematical modeling of the stress-strain state of the bone-implant systems showed that with given constraints (hand abduction to 90°), the use of two polylactic acid implants can reduce the stress in the plate and screws, respectively, by 11% and 6% .

CONCLUSION

Conclusions

The use of polylactic acid implants during osteosynthesis of three- and four-fragment fractures of the proximal humerus, especially in the case of osteoporosis, allows providing for the reinforcement of metal structures and supporting of the articular surface without deterioration of fixation rigidity.

Для цитирования: Korzh Mykola O, Makarov Vasyl B, Lipovsky Volodymyr I, Morozenko Dmytro V, Danylchenko Svitlana I. Mathematical modeling of the stress-strain state of the "bone-implant" system during the osteosynthesis with a philos with polylactic acid implants.. Wiadomosci lekarskie (Warsaw, Poland : 1960). 2020.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.